Oblique direction reach test: evaluating psychometric properties in stroke population

Author:

Mascarenhas Rinita1,Nayak Akshatha1,Joshua Abraham M.1,Krishnan Shyam K.1,Iyer Vani Lakshmi R.2,Tedla Jaya Shanker3ORCID,Reddy Ravi Shankar3ORCID

Affiliation:

1. Department of Physiotherapy, Kasturba Medical College, Mangalore, Manipal Academy of Health Education, Manipal, India

2. Department of Data Science, Prasanna School of Public Health, Manipal, Manipal Academy of Health Education, Manipal, India

3. Department of Medical Rehabilitation Sciences, College of Applied Medical Science, King Khalid University, Abha, Saudi Arabia

Abstract

Background Post-stroke individuals are observed to have reduced limits of stability (LOS) in all directions. Functional activities are rarely performed in pure cardinal planes; instead, they are most likely to be performed in an oblique direction. Existing tools are either expensive or sophisticated to assess the LOS in an oblique direction. Therefore, this study’s primary objective is to evaluate the intra-rater, inter-rater reliability, and validity of the oblique direction reach test (ODRT) among stroke subjects. Materials & Methods A total of 96 first-time stroke patients with age, gender, height, and weight-matched healthy controls aged 18–80 years were recruited for the study. Oblique, forward, and lateral reach distances were assessed using the standard procedure of ODRT, Functional Reach Test (FRT), and Lateral Reach Test (LRT), respectively. Validity was tested by correlating the ODRT distance with the Berg Balance Scale (BBS) Score using Spearman’s rank correlation coefficient. Intraclass correlation coefficients (ICCs) and Bland Altman analysis were used to establish inter-rater reliability. ICCs were used to find intra-rater reliability. The Mann-Whitney U test was used to establish the mean difference of the FRT, LRT, and ODRT. Spearman’s rank correlation coefficient and linear regression were used to correlate the distance of FRT and LRT with ODRT. Results A high concurrent validity was found between BBS and ODRT with an r-value of 0.905 (p < 0.001). Inter-rater reliability was high with an ICC of 0.997 (95% CI [0.996–0.998]), and intra-rater reliability was highly significant with an ICC of 0.996 (95% CI [0.994–0.998]). The stroke subjects reached a significantly shorter distance than healthy individuals in FRT, ODRT, and LRT. ODRT was highly correlated with FRT (r = 0.985) and LRT (r = 0.978) (p < 0.001) and had an R2 = 0.987. Conclusion ODRT is a highly valid and reliable tool that can be used to evaluate balance in stroke patients. Individuals who reached less in the forward and lateral directions showed reduced reach distance in the oblique direction.

Funder

Deanship of Scientific Research at King Khalid University

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

Reference28 articles.

1. Measuring balance in the elderly: preliminary development of an instrument;Berg;Physiotherapy Canada,1989

2. Usefulness of the berg balance scale in stroke rehabilitation: a systematic review;Blum;Physical Therapy,2008

3. Test-retest reliability and construct validity of the tinetti performance-oriented mobility assessment in people with stroke;Canbek;Journal of Neurologic Physical Therapy,2013

4. Normal values of functional reach and lateral reach tests in Indian school children;Deshmukh;Pediatric Physical Therapy: The Official Publication of the Section on Pediatrics of the American Physical Therapy Association,2011

5. Functional reach: a new clinical measure of balance;Duncan;Journal of Gerontology,1990

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3