Percutaneous Balloon Pulmonary Valvuloplasty of Critical Pulmonary Stenosis and severe pulmonary stenosis in Neonates and Early Infancy: A Challenge in the Cyanotic

Author:

Mortezaeian Hojjat1ORCID,khorgami Mohammadrafie1ORCID,Omidi Negar2,khalili Yasaman1,Moradian Maryam1,Zamani Raheleh1,Nazari Esfandyar1

Affiliation:

1. Rajaie Cardiovascular Medical and Research Center, Iran University of medical sciences, Tehran, Iran

2. Cardiac Primary Prevention Research Center, Tehran Heart Center and Department of Cardiology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran

Abstract

Introduction: Pulmonary stenosis with an intact ventricular septum (PS-IVS) is one of the common causes of cyanotic heart disease in neonates with diverse morphologies as well as management and treatment protocols. The aim of this study was to evaluate short and midterm results of balloon pulmonary valvuloplasty (BPV) for this disorder. Methods: Between 2012 and 2016, Totally 45 neonates and infants under 6 months old were evaluated.The patients had a minimum right-to-left ventricular pressure ratio of 1, right-to-left shunting at the patent foramen ovale or atrial septal defect level, and tricuspid valve Z-scores higher than -4. Results: Immediately after the procedure, the right ventricular pressure dropped to the normal values in 8 (20%) patients. The immediate procedural success rate was seen in 42 (93.3%) cases: the right-to-left ventricular pressure ratio dropped to below 50% or the level of O2 saturation rose above 75%. Of three cases unresponsive to BPV, two of them underwent patent ductus arteriosus (PDA) stenting and one procedural death occurred. At 6 months’ follow-up, of 42 patients, this pressure was still with in the normal range in 36 (80%) infants, while it had returned to high values in 9 (20%) patients and necessitated repeat valvuloplasty. After BPV, severe pulmonary valve regurgitation was observed in14.2% patients; the condition was more common when high-profile noncompliant balloons were used. Conclusion: Balloon pulmonary valvuloplasty in infants with PS-IVS confers acceptable results insofar as it improves echocardiographic parameters and hemodynamic changes at short- and midterm followups.Balloon selection with sizes more than 1.2 of the diameter of the pulmonary valve annulus and the use of noncompliant high-pressure balloons results in higher degrees of pulmonary regurgitation.

Publisher

Maad Rayan Publishing Company

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3