Abstract

Abstract Background and Objectives: Water quality is important for preparation of dialysis solution due to its direct relationship with blood of patients with renal failure. The aim of this study was to evaluate the chemical and microbial quality of inlet and outlet water of dialysis devices in hospitals of East Azerbaijan province. Material and Methods: This study was a descriptive-analytical study in which the water of dialysis ward of three hospitals affiliated to East Azerbaijan University of Medical Sciences was investigated. The results of physicochemical (45 cases) and microbial (163 cases) of dialysis water were extracted from the relevant archives in two stages before and after reverse osmosis treatment during 2014-2016. Independent t-test and one-way ANOVA were used for statistical analysis while extracting descriptive statistical parameters. Data analysis was done using Excel and SPSS 23 software. Results: Evaluation of the efficiency of reverse osmosis system showed that there was a significant difference between water quality, before and after the system. Except for calcium, magnesium, fluoride and nitrate, the concentrations of other cations and anions in 100% of samples were lower than the European Pharmacopoeia standard. Incoming water samples to dialysis machine in 4.9% of cases had total coliform contamination and there was no fecal coliform in any of the samples. The frequency and frequency of tests in hospitals are not observed and despite the risk of heavy metals, heavy metals tests are not performed on dialysis water for the health of dialysis patients. Conclusion: The need to develop a national standard for controlling dialysis water, testing all quality parameters of dialysis water according to standards in regular times and timeframes, informing hospital managers and environmental health experts about the importance of dialysis water quality in health and increasing life expectancy of dialysis patients is felt.

Publisher

Maad Rayan Publishing Company

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3