Affiliation:
1. Department of Oral and Maxillofacial Radiology, Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Qazvin, Iran
2. Student Research Committee, Qazvin University of Medical Sciences, Qazvin, Iran
Abstract
Background. Dental caries is the most important reason for tooth loss. Clinical examination is the most commonly used technique for occlusal caries diagnosis. The diagnostic power of digital systems is a matter of controversy in this field. The present study aimed to determine the diagnostic accuracy of two photostimulable phosphor plate (PSP) systems for early occlusal dentin caries in vitro. Methods. Sixty-nine extracted molar and premolar teeth were used in this study. The teeth were mounted in triple blocks, and standard radiographs were taken by the Digora and Acteon digital radiographic systems. The original and filter 1-enhanced radiographs were evaluated by two experienced observers twice at an interval of two weeks, and dentin caries was recorded in Tables prepared for the study. The teeth were then sectioned in a buccolingual direction and evaluated under a stereomicroscope. The observers’ reports were compared with microscopic findings as the gold standard. SPSS 23 was used to calculate the kappa coefficient, sensitivity, specificity, and area under the ROC curve (AUC). Statistical significance was set at P<0.05. Results. The internal and the external agreements in both imaging systems were good to excellent. The means of sensitivity, specificity, and AUC in the Acteon system were 34.1, 92.9, and 0.674, with 30.8, 94.8, and 0.659, respectively, in the Digora system. Conclusion. The accuracy of early occlusal caries diagnosis was poor on both systems, and no significant difference was observed between the two systems at a 95% confidence interval. Although the AUC was slightly higher in the original images, there was no significant difference between them; however, due to their high specificity, they can prevent unnecessary treatments in the clinic.
Publisher
Maad Rayan Publishing Company
Reference26 articles.
1. Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries
2. Marami A, Noormohammadi R, Javaheri M. In vitro comparison of the accuracy of Primax, Insight Dental X-Ray films and CMOS-APS digital imaging in detection of interproximal caries. Journal of Shahid Sadoughi University of Medical Sciences 2009;16(4):33-40. [Persian].
3. Comparing the Diagnostic Accuracy of Two Different Resolutions of
Radiographs Captured with PSP Digital Intraoral Receptors in
Detection of Secondary Caries (In Vitro)
4. Comparing between the power of CCD and PSP digital intraoral receptors in detection of secondary proximal caries in permanent premolar teeth (In Vitro);Talaeipour A;J Res Dent Sci,2016
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献