Evaluation of microhardness in two types of denture bases after using sodium hypochlorite and NatureDent disinfecting agents

Author:

Moslehifard Elnaz1ORCID,Ghaffari Tahereh1,Zarei Khosro2ORCID,Karimoghli Mahsa1ORCID

Affiliation:

1. Department of Prosthodontics, Tabriz University of Medical Sciences, Tabriz, Iran

2. Department of Prosthodontics, Kurdistan University of Medical Sciences, Kurdistan, Iran

Abstract

Background. Chemical agents, in combination with mechanical methods, play an important role in reducing microbial plaque on denture surfaces. However, these methods might change the mechanical behavior of acrylic resins, including microhardness and surface roughness. This in vitro study investigated the effect of two disinfectants, i.e., water and sodium hypochlorite, on the microhardness of conventional heat-cured and TiO2 nanoparticle-reinforced acrylic resins. Methods. Sixty acrylic resin specimens were divided into two groups, and the samples in each group were randomly assigned to three subgroups (n=10). Heat-cured specimens and 1 wt% TiO2 acrylic resin were prepared and immersed in three solutions: water, a solution prepared with NatureDent pills, and 1% sodium hypochlorite for 30, 60, and 90 days. Microhardness tests were performed on each sample at each immersion stage. The data were analyzed using descriptive statistical methods, three-way and one-way ANOVA, repeated-measures t test, and Tukey HSD tests using SPSS 17. P values<0.05 were considered significant. Results. All three independent parameters, including resin, solution, and time, significantly affected microhardness (P<0.05). The microhardness of both specimen types, i.e., conventional heat-cured and TiO2 nanoparticle-reinforced acrylic resins, immersed for 30, 60, and 90 days, was the highest and lowest in water and hypochlorite solutions, respectively. Regarding 90 days, the microhardness values of conventional heat-cured and TiO2 nanoparticle-reinforced acrylic resins were 17.050±0.094 and 19.953±0.053 in water, 15.675±0.069 and 18.965±0.037 in hypochlorite, and 16.713±0.122 and 19.39±20.113 in NatureDent solutions, respectively. Conclusion. Disinfecting two types of acrylic resin specimens decreased their microhardness as a function of immersion time for up to 90 days in the three solutions. However, the magnitude of hardness lost was less for TiO2 nanoparticles-reinforced acrylic resin.

Publisher

Maad Rayan Publishing Company

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3