Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery

Author:

Perthel Mathias1,Kseibi Samer1,Bendisch Andreas1,Laas Joachim2

Affiliation:

1. Herz-Kreislauf-Klinik Bevensen, Department for Cardiothoracic Surgery, Bad Bevensen, Germany

2. Herz-Kreislauf-Klinik Bevensen, Department for Cardiothoracic Surgery, Bad Bevensen, Germany,

Abstract

Neurological complications remain an important cause of morbidity and mortality of patients following cardiopulmonary bypass (CPB). Microemboli, as well as cerebral hypoperfusion, are the main postulated mechanisms. This study demonstrates that the insertion of a dynamic bubble trap (DBT) into the curcuit reduces microbubbles in the arterial line and microembolic signals (MES) in the middle cerebral arteries (MCAs). We investigated 12 patients during coronary artery bypass grafting (CABG). The DBT was inserted between the arterial filter and the arterial cannula. For detection of microemboli before and after the DBT, a special ultrasound Doppler device was used. MES were detected by transcranial Doppler monitoring in both MCAs of the patients. Microbubbles and MES were counted during bypass. These data were compared to 12 patients who were operated in a previous period without the use of a DBT. There were no significant differences in both groups with respect to gender, age, crossclamp and bypass time and number of anastomoses. In the group without a DBT in the circuit, a mean of 6311 microbubbles per operation could be observed distal to the arterial filter, corresponding to 282 MES. After inclusion of a DBT, we could register, in the second group, 8496 microemboli proximal and 2915 distal of the DBT, corresponding to 89 MES per operation. The reduction rate of microbubbles in the tubing was 65.7%, corresponding to a reduction in MES of about 86.2%. We conclude that the insertion of a DBT in the arterial line of CPB circuit protects the cerebrovascular system from microembolic events, as demonstrated by lower MES counts.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3