Abstract

Background: Cardiopulmonary bypass (CPB) in neonates and infants is associated with significant haemodilution when priming of the CPB circuit is accomplished without transfusion of homologous blood components. The degree of haemodilution and, thus, the requirements for blood transfusion may be reduced when the CPB circuit is miniaturized without compromising patient safety. Method: Between January 2002 and October 2003, selected neonates and small infants were operated on using a nonhaemic prime extracorporeal circuit. CPB priming volume could be reduced from 300 mL to 190 mL by using a dedicated neonatal CPB console with mast-mounted roller pump heads. Reduction of priming volume resulted from shortening of all CPB lines to the minimum, downsizing of all CPB lines, exclusion of unused CPB components, use of vacuum-assisted venous drainage and from close co-operation between the perfusionist, cardiac surgeon and anaesthesiologist. The reduction in priming volume was achieved without eliminating the arterial line filter as safety device. Results: A total of nine patients weighing between 3.2 and 5.9 kg (mean 4.7 kg) and with a body surface area of 0.22 - 0.35m2 (mean 0.29m2) were operated on with the use of the modified neonatal CPB circuit and a nonhaemic prime. Bypass time varied from 38 to 167 min (mean 96 min). The mean haematocrit on CPB was 22.5% with a range of 17 - 29%. The postoperative course of all patients was uneventful. Conclusion: A significant reduction in CPB priming volume makes nonhaemic prime CPB in neonates and small infants undergoing complex repair of congenital heart defects possible.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3