Conventional approach to glucose management for diabetic patients undergoing coronary artery bypass surgery

Author:

Gustafson Patricia A1,Zarro Debra L2,Palanzo David A2,Manley Norman J2,Montesano Ralph M2,Quinn Michael2,Elmore Barbara-Anne2,Castagna Joseph M2

Affiliation:

1. Perfusion Care Associates, Inc. and the Lehigh Valley Hospital, Allentown, Pennsylvania, USA,

2. Perfusion Care Associates, Inc. and the Lehigh Valley Hospital, Allentown, Pennsylvania, USA

Abstract

Continuous insulin infusion was not an effective mode of treatment in maintaining safe blood glucose levels (<200 mg/dl) during the intraoperative period of diabetic patients requiring open-heart surgery. The two modifications investigated to gain better control of the blood glucose were a change in the base solution of the cardioplegia and the use of a sliding insulin scale. Fifty patients including Type I and Type II diabetics were selected for the purpose of this study. The patients were then randomly divided into two groups categorized by the type of cardioplegic solution administered and the mode of insulin treatment. Group I patients received a dextrose 5%-based cardioplegic solution and blood glucose was treated via continuous intravenous insulin infusion. Group II patients received normal saline 0.9%-based cardioplegic solution and blood glucose was treated via sliding scale. Blood glucose levels were monitored pre- and postcardio- pulmonary bypass (CPB) and every 30 min while on CPB. Glucose values were analyzed by group t test. A p value of < 0.05 was considered statistically significant. When comparing Group I (mean=258 mg/dl) with Group II (mean= 158 mg/dl), there was a statistically significant difference between the glucose values at each of the time intervals when the glucose values were recorded. In conclusion, Group II maintained an acceptable blood glucose level (<200 mg/dl) throughout the entire intra- operative period, which suggests that the combination of the sliding insulin scale and modification of the base cardioplegic solution was an effective mode of treatment.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3