Abstract

Rapid volume replacement for severe hemorrhage continues to challenge the clinician involved in the care of the patient suffering hemorrhagic shock. We report on the development and utilization of two rapid-infuser systems for volume replacement in critically ill patients presenting in extremis. We have developed rapid-infusion circuits by using commercially available devices available at our institution. The primary pumping mechanism is either a centrifugal pump (Revolution™COBE Cardiovascular, Arvada, CO, USA), or the Myocar-dial Protection System (MPS™ - Quest Medical, Allen, TX, USA), and offers advantages over commercially available devices. Both circuits consist of a cardiotomy reservoir, a cardioplegia delivery set, assorted tubing and connectors, and a heater-cooler system. Between January and October of 2003, 15 procedures were performed which utilized one of these two devices. There were nine ruptured aneurysms, five traumas and one radical nephrectomy. The rapid infusion time averaged 228.59±105.7 min where 10.49±9.4 L of autotransfusion volume was processed, with 3.99±4.2 L of red cell volume reinfused. The allogeneic blood products that were transfused included packed red blood cells and fresh frozen plasma, as well as 5% albumin. There were no intraoperative deaths and the rapid-infuser was considered lifesaving in all instances. Mechanical rapid infusion systems may be lifesaving when severe hypovolemia or hemorrhagic shock is encountered. While both devices are able to meet the requirements of rapid fluid replacement, the MPS offers the most safety features and has become the standard of care at our institution.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3