Leukocyte filtration and miniature perfusion during arrested heart CABG on a Jehovah’s Witness patient

Author:

Sutton Steven W1,Duncan Michael A2,Chase Virginia A2,Cheung Edson H3,Hamman B L3

Affiliation:

1. Baylor University Medical Center, Dallas, TX, USA,

2. Baylor University Medical Center, Dallas, TX, USA

3. Department of Thoracic and Cardiovascular Surgery, Baylor University Medical Center, Dallas, TX, USA

Abstract

Bloodless surgery and a reduction in the use of allogeneic blood products has long been the standard of care in medicine. Many individuals in our communities have demanded this form of surgical treatment for personal and religious reasons. On 6 December 2002, a 72-year-old male patient was admitted to our institution as a critical air flight transfer. The patient’s height was 190.5 cm and weight was 59.3 kg (body surface area 1.83 m2). His preliminary diagnosis was chest pain with myocardial infarction as evidenced by elevated blood cardiac isoenzymes. His principle diagnosis was subendocardial infarction with paroxysmal ventricular tachycardia. Cardiac catheterization was performed and demonstrated severe triple vessel disease with an ejection fraction of 30%. He was evaluated and accepted as a candidate for coronary artery bypass grafting. Multidisciplinary consultation concluded that a safe and effective method of perioperative treatment would involve the use of arrested heart support with cold blood cardioplegia using a low prime miniature perfusion circuit as no blood products would be considered for use. Additionally, the combined modalities of perfusion interventions to minimize hemodilution consisted of intraoperative autologous blood collection totaling 500 mL and rapid autologous priming of the miniature perfusion circuit. The miniature perfusion system was a low prime Cardiovention (Santa Clara, CA) CORx device which includes a hollow-fiber oxygenator and integral centrifugal pump with a surface area of 1.2 m2. This system also incorporates an air sensing solenoid which triggers rapid air evacuation in a bolus range of 1 mL or greater. Kinetic venous drainage is another feature of this device as the centrifugal pump is integrated into the oxygenator. We believed that a miniature extracorporeal circuit would enhance the desired clinical outcome as opposed to the risk of: (1) off-pump coronary artery bypass (OPCAB) approach and the concern of emergent transition to an on-pump procedure and (2) use of larger surface area with conventional systems that impose a greater hemodilutional effect. Leukocyte filtration was employed as the patient had a significant past medical history of chronic obstructive pulmonary disease. We herein report our clinical experience with this method of treatment on a patient who refused the use of blood products in his surgical treatment. It is our belief that the multiple modalities utilized in combination during this procedure resulted in positive clinical outcomes as demonstrated by an intubation time of 8 hours 35 min with a discharge on the fifth postoperative day.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3