Purpose: Evaluate the feasibility and clinical significance of crystalloid prime reduction during the initiation of cardiopulmonary bypass (CPB) using a modified bridge on the cardioplegia delivery system. Methods: Prospective trial of crystalloid prime reduction using a standard Duraflow®-coated CPB circuit and Vanguard® 2:1 cardio plegia delivery system. Standard prime volume was 1500 cc of Plasmalyte. Prime was reduced via the bridge in the cardioplegia system during initiation of CPB. Packed red blood cells (PRBC) were transfused for hematocrit (Hct) less than 24% while rewarming. A hemoconcentrator was used if the patient’s circulating blood volume exceeded 150% of calculated. All data were prospectively collected. Results: Two hundred and twenty-two consecutive patients undergoing cardiac surgery utilizing CPB were evaluated. There were 107 patients with normal prime volume (NPV) and 115 patients with reduced prime volume (RPV). There was no significant difference in sex, mean age, weight, body surface area (BSA), pre-op Hct, procedure time or procedure between the two groups. There was no difference in total crystalloids infused by the anesthetists (average NPV 1205 cc versus RPV 1148 cc). The average RPV was 622 cc (range 400 - 1100 cc) or a 59% reduction. Post-op Hct revealed no difference (NPV 28% versus RPV 29%). There was a 24% reduction in patients requiring PRBC (NPV n=23 versus RPV n=18). The use of hemoconcentrators was reduced by 49% (NPV n=18 versus RPV n=11). The average urine output for both groups exceeded 100 cc/hour while on CPB. Conclusion: Using a modified cardioplegia delivery system is a safe and effective method of CPB prime reduction. A RPV resulted in fewer patients requiring PRBC transfusions and fewer hemoconcentrators used. Based on our experience, we would recommend attempting to reduce prime volume in all patients undergoing CPB.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3