Comparison of conventional extracorporeal circulation and minimal extracorporeal circulation with respect to microbubbles and microembolic signals

Author:

Perthel M1,Kseibi S2,Sagebiel F2,Alken A2,Laas J2

Affiliation:

1. Department of Cardiothoracic Surgery, Herz-und Gefäßzentrum Bad Bevensen, Bad Bevensen, Germany,

2. Department of Cardiothoracic Surgery, Herz-und Gefäßzentrum Bad Bevensen, Bad Bevensen, Germany

Abstract

The intention of minimal extracorporeal circulation (MECC) is to reduce priming volume and minimize contact of blood with polymers and air in a closed system. In contrast to conventional extracorporeal circulation (ECC), a venous reservoir is missing. Thus, air trapping is limited and avoidance of bubble embolism is a major concern. This study investigates microbubbles (MBB) number and size in the venous and arterial lines of ECC and MECC compared to the number of microembolic signals (MES) in the right and left middle cerebral artery (MCA). Twenty patients undergoing coronary surgery were operated either with conventional ECC (cardiotomy reservoir, Rotaflow pump, Quadrox oxygenator, Quart filter) or MECC (Quart filter, Rotaflow pump, Quadrox oxygenator). Number and size of MBB were monitored in the venous and arterial lines with an ultrasound Doppler system. MES in right and left MCAs were measured by transcranial Doppler (TCD) monitoring. Patients undergoing MECC had additional sealing of the venous cannula by a ligature at the site of its insertion into the right atrium. There were no significant differences between groups with respect to age, X-clamping, bypass time and number of distal anastomoses. The number of MES and MBB in the arterial line was comparable between the groups. On the venous side, MECC-perfusion shows a significantly lower number of MBB. This could be explained with the additional sealing of the venous cannula. Furthermore, our data indicate that the MBB-volume reaching the pump will also appear in the arterial outflow and into the patient’s MCA. For this reason, the avoidance of air contamination is a major concern for surgeons, anaesthesiologists and perfusionists.

Publisher

SAGE Publications

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3