Microbiological Impacts of Decontamination of Stethoscopes and Assessment of Disinfecting Practices among Physicians in Pakistan: A Quality Improvement Survey

Author:

Tahir Muhammad Junaid12,Zaman Musharaf12,Babar Muhammad Saad12,Imran Fareeha123,Ajmal Aasma Noveen123,Malik Muna1234,Khan Jalees Khalid123,Ullah Irfan567,Asghar Muhammad Sohaib8

Affiliation:

1. Ameer-ud-Din Medical College, Affiliated with University of Health Sciences, Lahore, Pakistan;

2. Lahore General Hospital, Lahore, Pakistan;

3. Postgraduate Medical Institute, Lahore, Pakistan;

4. Medical Microbiology and Infectious Diseases Society of Pakistan, Karachi, Pakistan;

5. Kabir Medical College, Gandhara University, Peshawar, Pakistan;

6. Undergraduate Research Organization, Dhaka, Bangladesh;

7. Naseer Teaching Hospital, Peshawar, Pakistan;

8. Dow University of Health Sciences–Ojha Campus, Karachi, Pakistan

Abstract

ABSTRACT. The study was conducted to determine bacterial contamination of stethoscopes used by doctors before and after disinfecting with isopropyl alcohol and analyze their practices of disinfecting stethoscopes. Samples from stethoscopes were taken before and after disinfecting with 70% isopropyl alcohol swab with the help of a sterile swab. All swabs were inoculated on Blood and MacConkey agar plates and were examined for growth. Stethoscopes of 78 doctors were sampled which included 45 (58%) males and 33 (42%) females. Before decontamination of diaphragms with isopropyl alcohol, 27 (34.6%) diaphragms had “growth” while 51 (65.4%) had “no growth.” After decontamination with isopropyl alcohol, 5 (6.4%) had “growth” while 73 (93.6%) had “no growth.” The most common microorganism isolated from stethoscopes’ diaphragms was methicillin-resistant Staphylococcus epidermidis (MRSE), that is, 14 out of 78 (17.9%). The survey also evaluated factors associated with contamination of stethoscopes. Most doctors 71(91%) believe that stethoscopes can be a source of infection and 55.1% (N = 43) responded that both diaphragm and bell of stethoscopes can transmit infections. Many doctors (41%, N = 32) reported that “forgetfulness/laziness” was the barrier which they faced regarding stethoscope hygiene followed by “lack of time” (21.8%, N = 17). The contamination rate (66.6%) is highest in those doctors who are using their stethoscopes for 3–5 years. Of them, 30 doctors (38.5%) never decontaminated their stethoscopes among which 17 had growth in their stethoscopes before cleaning with isopropyl alcohol, while three had growth even after decontamination. Most doctors used sanitizer (29.5%) and isopropyl alcohol (25.6%) as cleaning agents.

Publisher

American Society of Tropical Medicine and Hygiene

Subject

Virology,Infectious Diseases,Parasitology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Impact of Plastic-Wrap Properties and Cleaning Intervals on the Disinfection of Elevator Buttons;International Journal of Environmental Research and Public Health;2023-01-16

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3