Real-Time Fluorimetry Loop-Mediated Isothermal Amplification for Diagnosis of Leishmaniasis and as a Tool for Assessment of Cure for Post–Kala-Azar Dermal Leishmaniasis

Author:

Dixit Keerti Kaumudee12,Ramesh Venkatesh3,Gupta Ratan4,Negi Narendra Singh5,Singh Ruchi1,Salotra Poonam1

Affiliation:

1. 1ICMR-National Institute of Pathology (NIOP), Safdarjung Hospital Campus, New Delhi, India;

2. 2Faculty of Health and Biological Sciences, Symbiosis International (Deemed University), Pune, India;

3. 3Department of Dermatology and STD, Safdarjung Hospital, Vardhman Mahavir Medical College, New Delhi, India;

4. 4Department of Paediatrics, Safdarjung Hospital, Vardhman Mahavir Medical College, New Delhi, India;

5. 5Department of Medicine, Safdarjung Hospital, Vardhman Mahavir Medical College, New Delhi, India

Abstract

Abstract.Despite the dwindling number of visceral leishmaniasis (VL) cases in India, there is an urgent need for early and unequivocal diagnostics for controlling and preventing the reemergence of VL. Post–kala-azar dermal leishmaniasis (PKDL), a dermal sequela of VL, serves as a reservoir of the parasite. Diagnosis of PKDL, especially the macular variant, is challenging and poses impediment toward attainment of VL elimination. In this study, a real-time fluorimetry loop-mediated isothermal amplification (RealAmp) assay has been established for the detection of different clinical manifestations of leishmaniasis. The study included 150 leishmaniasis patients (25 VL, 25 cutaneous leishmaniasis [CL], and 100-PKDL) along with 120 controls. The assay demonstrated sensitivity of 100% (95% CI: 86.68–100) for diagnosis of VL and PKDL (95% CI: 79.61–100) and 96% (95% CI: 86.68–100) for CL with 100% specificity. Moreover, considering the cardinal role of PKDL, diagnosis using minimally invasive slit aspirate was explored, which demonstrated remarkable sensitivity of 96% (95% CI: 87.64–98.47). As a test of cure for PKDL, RealAmp successfully detected parasite in two of posttreatment cases who later reported relapse on follow-up. Also, direct sample lysis using slit aspirate was attempted in a small group that yielded sensitivity of 89% (95% CI: 67.20–96.90). RealAmp depicted excellent diagnostic accuracy in the diagnosis of leishmaniasis in concordance with the established SYBR Green I–based (Molecular Probes, Eugene, OR) visual loop-mediated isothermal amplification (LAMP) and the reference comparator real-time PCR. The study endorsed the employment of LAMP either as visual-LAMP or RealAmp for an accurate and expeditious diagnosis of PKDL and as a tool for assessment of cure.

Publisher

American Society of Tropical Medicine and Hygiene

Subject

Virology,Infectious Diseases,Parasitology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3