Rapid and Comprehensive Screening for Urogenital and Gastrointestinal Schistosomiasis with Handheld Digital Microscopy Combined with Circulating Cathodic Antigen Testing

Author:

Coulibaly Jean T.12,Silue Kigbafori D.12,de León Derby María Díaz3,Fletcher Daniel A.345,Fisher Karla N.67,Andrews Jason R.8,Bogoch Isaac I.679

Affiliation:

1. Unité de Formation et de Recherche Biosciences, Université Félix Houphouët-Boigny, Abidjan, Côte d’Ivoire;

2. Centre Suisse de Recherches Scientifiques en Côte d’Ivoire, Abidjan, Côte d’Ivoire;

3. Department of Bioengineering, University of California, Berkeley, Berkeley, California;

4. Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, Berkeley, California;

5. Chan Zuckerberg Biohub, San Francisco, California;

6. Division of General Internal Medicine, Toronto General Hospital, University Health Network, Toronto, Canada;

7. Division of Infectious Diseases, Toronto General Hospital, University Health Network, Toronto, Canada;

8. Division of Infectious Diseases and Geographic Medicine, Stanford University School of Medicine, Stanford, California;

9. Department of Medicine, University of Toronto, Toronto, Canada

Abstract

ABSTRACT. Novel methods are required to aid the monitoring of schistosomiasis control and elimination initiatives through mass drug administration. Portable digital and mobile phone microscopy is a promising tool for this purpose. This cross-sectional study evaluated the diagnostic operating characteristics of a converted mobile phone microscope (the SchistoScope) for the detection of Schistosoma haematobium eggs, as determined by community-based field workers and expert microscopists, compared with a field gold standard of light microscopy. Three hundred sixty-five urine samples were evaluated by conventional light microscopy, with 49 (13.4%) positive for S. haematobium. Compared with light microscopy, the sensitivity and specificity of S. haematobium detection by field microscopists trained to use the SchistoScope were 26.5% (95% CI: 14.9–41.1%) and 98.4% (95% CI: 96.3–99.5%), respectively. The sensitivity and specificity of S. haematobium detection by expert microscopists using the SchistoScope was 74% (95% CI: 59.7–85.4%) and 98.1% (95% CI: 95.9–99.3%), respectively, compared with light microscopy. The sensitivity rose to 96.1% and 100% when evaluating for egg counts greater than five and 10 eggs per 10 mL, respectively. A point-of-care circulating cathodic anion (POC CCA) test was used to evaluate Schistosoma mansoni; however, there were too few positive samples to reliably comment on diagnostic characteristics. This study demonstrated that a “urine-only” approach to rapidly screen for schistosomiasis at the point of sample collection can be conducted with mobile phone microscopy (S. haematobium) coupled with POC CCA (S. mansoni). Such an approach may aid in streamlined schistosomiasis control and elimination initiatives.

Publisher

American Society of Tropical Medicine and Hygiene

Reference20 articles.

1. Underestimation of the global burden of schistosomiasis;King,2018

2. Human schistosomiasis;Colley,2014

3. The pathology, pathobiology and pathogenesis of schistosomiasis;Warren,1978

4. WHO Guideline on Control and Elimination of Human Schistosomiasis,2022

5. Diagnostic Target Product Profiles for Monitoring, Evaluation and Surveillance of Schistosomiasis Control Programmes,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3