Reconstruction of a hip socket using trabecular metal components

Author:

Zagorodny N. V,Alexanyan O. A,Cragan G. A,Kagramanov S. V,Iwunze B. U

Abstract

Introduction. Fixation of the acetabular component in patients with bone defects of the acetabulum is a difficult task due to the insufficient quantity and poor quality of the remaining bone tissue. During the last few years in our country in arthroplasty of the acetabulum with severe bone defects were actively used implants made of trabecular metal. Purpose of study: was to evaluate short-term clinical and radiological results of the usage of trabecular metal components in patients with bone defects in revision and primary hip replacement. Patients and methods. 59 surgeries were performed using components of trabecular metal, 53 of them were performed on the instability of the hip prosthesis, 2 - post-traumatic hip dysplasia, 2 - aseptic necrosis of the femoral head, 2 - high dislocation of the femoral head. Among the operated there were 37 women and 22 men, the average age was 58.2±19.9 years. According to the Paprosky classification, defects in 12 cases corresponded to type IIA, in 14 - type IIB, in 6 - type II, in 19 - type IIIA, in 7 - type IIIB. The structural features of these implants, made of tantalum in a carbon skeleton with uniform porosity, similar to the structure of bone tissue, provide an increased coefficient of friction, thereby contributing to the rapid growth of bone tissue in the implant structure. Results. The average follow-up period was 14 months. The average preoperative assessment of the hip joint by Harris Hip Score (HHS) was 43 points (from 14 to 86). After surgery, the average HHS improved to 88.7 (69 to 100). 1 patient had hemorrhagic discharge after surgery. On the 7th day an audit was performed. In 2 cases, paresis of the peroneal portion of the sciatic nerve developed after surgery. There were no cases of recurrent dislocations, deep infection, pulmonary embolism or death as a result of operations. Conclusion. Taking into account the mechanical properties, tantalum implants allow to achieve a stable primary fixation with the restoration of the center of rotation of the hip joint and eliminate the risks associated with the use of allografts. Conflict of interest: the authors state no conflict of interest Funding: the study was performed with no external funding

Publisher

ECO-Vector LLC

Subject

General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3