Affiliation:
1. San Antonio, Texas
2. Otology Group-San Antonio, PA, San Antonio, Texas
Abstract
OBJECTIVE: We sought to compare the findings of 3 different hearing screening methods in school-aged children. STUDY DESIGN AND SETTING: Prospective testing of second- and third-grade students in their schools was carried out. METHODS: Three hundred children (599 ears) were screened by using 3 test modalities, pure-tone audiometry, distortion product otoacoustic emissions (DPOAE), and tympanometry. RESULTS: All of the tests were normal in 532 ears (89%), and all were abnormal in 12 ears (2%). Tympanometry yielded the most abnormalities (8.3%), and pure-tone testing demonstrated the fewest (3.3%), with a positive rate of 6.3% for DPOAE testing. False-positive rates were 1.2%, 4.2%, and 6.4% for pure tones, DPOAE, and tympanometry, respectively, when normal results on pure-tones or DPOAE were taken to represent true hearing. CONCLUSION/SIGNIFICANCE: We continue to recommend pure-tone testing as an effective screening method, with follow-up by using otoacoustic emissions in those who fail the pure-tone test.
Subject
Otorhinolaryngology,Surgery
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献