Author:
Wuillemin Zacharie,Nakajo Arata,Müller Andres,Schuler Andreas J.,Diethelm Stefan,Van Herle Jan,Favrat Daniel
Abstract
The locally-resolved degradation behavior was studied during 1900 hours in a SOFC repeat-element. In-situ measurements of local electrochemical performance were made on 18 locations over a segmented anode-supported cell. The evolution of local current densities, overpotentials and area-specific resistances was studied, showing a reorganization of the electrochemical reaction with time. The extent and the spatial distribution of degradation were established for different electrochemical reactions steps using impedance spectroscopy. The low-frequency cathode contribution was the mostly altered process, followed by the charge transfer reaction on anode side. Post-experiment analyses allowed to identify three major pollutants on the cathode side (chromium, silicon and sulfur), whose spatial distributions corresponded to the observed local degradation. Chromium was present only near the air inlet, while silica was found to affect a larger area, with decreasing amounts along the flow. Sources of pollutants were identified in system components as well as within the stack repeat-element.
Publisher
The Electrochemical Society
Cited by
32 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献