Author:
Schuler J. Andreas,Schuler Albert J.,Wuillemin Zacharie,Hessler-Wyser Aïcha,Ludwig Christian,Van Herle Jan
Abstract
This study aims to quantify in a holistic approach chromium (Cr) contamination in solid oxide fuel cell (SOFC) stack testing using adapted tools: i) a hot gas sampling method to analyze volatile Cr species in the air flux at the cathode inlet location; ii) a rapid quantification method for Cr as condensed matter in cathode material of post-test samples. The hot air sampling method reveals itself as a reproducible and time-resolved quantification technique for Cr trace amounts in a gas flow; this technique is seen as a promising evaluation tool for Cr contamination issues in SOFC systems. The quantification method reveals severe Cr-poisoning in a cell. The combined findings indicate that Cr contamination generated by system components located upstream the cell must be suppressed by hindering the access of Cr pollutants to the cathode compartment.
Publisher
The Electrochemical Society
Cited by
6 articles.
订阅此论文施引文献