Abstract
This work presents a platinum wire micro-reference electrode suitable for recording in-operando individual electrochemical impedance spectra of both the anode and the cathode in a proton exchange membrane water electrolyzer. The setup enables the protonic membrane potential to be accessed outside the active area. The reference electrode allows for the analysis of kinetic parameters for anode and cathode reactions separately. However, the exact location of the measured membrane potential is unknown due to a potentially asymmetric potential distribution, which makes the calculation of exact kinetic parameters non-trivial. Qualitative analyses of the potential distribution behavior over temperature, cell compression, and current density are shown.
Funder
Federal Ministry of Economic Affairs and Climate Action of Germany
Publisher
The Electrochemical Society
Subject
Materials Chemistry,Electrochemistry,Surfaces, Coatings and Films,Condensed Matter Physics,Renewable Energy, Sustainability and the Environment,Electronic, Optical and Magnetic Materials