Abstract
The transient electrochemical behavior of the Yb (III) ion (Yb3+) on the surface of a Ni working electrode in a (LiF–CaF2)eut.–Yb2O3 molten salt system was analyzed using a three-electrode system with a reversible (Ni2+/Ni) internal reference electrode and Pt external reference electrode. The (Ni2+/Ni) internal reference electrode exhibited good stability and reliability, and provided results that were consistent with those of the Pt external reference electrode. The (Ni2+/Ni) electrode also had a wider measurement window for analysis of the electrochemical process than that of the Ni working electrode. Cyclic voltammetry, square wave voltammetry, chronopotentiometry, and chronoamperometry were used to analyze the Yb3+ ion in the (LiF–CaF2)eut.–Yb2O3 (0.03 mol%) system. It was confirmed that the Yb3+ ion was reduced according to Yb3+ + e → Yb2+ and Yb2+ + 2e → Yb, and the electrode reaction process was quasi-reversible and controlled by diffusion. Moreover, the Yb3+ ion alloyed with the Ni electrode to form a Ni–Yb alloy.
Funder
Education Department of Jiangxi Province
National Natural Science Foundation of China
Publisher
The Electrochemical Society
Subject
Materials Chemistry,Electrochemistry,Surfaces, Coatings and Films,Condensed Matter Physics,Renewable Energy, Sustainability and the Environment,Electronic, Optical and Magnetic Materials
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献