Strategies for Reducing the Ohmic Resistance in a Proton Exchange Membrane Electrolysis Cell

Author:

Song Jie,Guo ZhiyuanORCID,Xu Guizhi,Zhu Yuting,Hou Kun,Ke Shaojie,Xu Chao

Abstract

Ohmic polarization caused by the contact resistance between components and their own bulk resistance is the main polarization loss in proton exchange membrane electrolysis cells. To investigate this, we adopted an electrolysis cell with an active area of 25 cm2 and explored methods of reducing ohmic resistance. First, two kinds of polar plate were designed to investigate the contact area between transport layer and catalytic layer. The results showed that the polar plate with the higher ridge area made the transport layer and catalytic layer achieve good contact, resulting in an ohmic resistance decreases of 17.5 mΩ cm2 when the contact area increases from 16.85 to 21.6 cm2. Second, Pt coating was used to prevent oxidation of the titanium felt and improve electrolytic performance. Sputtering titanium felt exhibits the best performance with the electrolysis voltage of 1.814 V at 2 A cm−2. Finally, we studied different proton exchange membranes and analyzed the performance and hydrogen permeation rate with the self-made membrane electrode, finding that the electrolytic voltage of the Solvay E98–05 S reaches 1.733 V at 2 A cm−2 due to the minimum thickness and the highest conductivity, and the H2 permeation current density is only 2.184 mA cm−2.

Funder

National Key R&D Program funding project

Publisher

The Electrochemical Society

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3