Abstract
The effect of anodic polarization in molten Na2CO3-K2CO3 at 750 °C was investigated on the structure of oxide scale formed by pre-oxidation of Ni-11Fe-10Cu-6Al alloy at 950 °C in air. The pre-formed oxide scale evolves and rearranges under anodic polarization related to melt corrosion and non-uniformly distributed electric field. Both of pre-oxidized and as-rearranged electrodes can serve as inert anodes with oxygen evolution. Anodic polarization exhibits a negative rearrangement-destructivity effect for the pre-formed oxide scale with corrosion protection of the rearranged oxide scale decreasing. The structure rearrangement of pre-formed oxide scale is also discussed during anodic polarization in the melt.
Funder
Open Fund of Hubei Key Laboratory of Biological Resources Protection and Utilization
Key Program of the Scientific Research Foundation of the Education Bureau of Hubei Province
National Natural Science Foundation of China