Abstract
This study focuses on the visualization of a charge-transfer complex, namely a Meisenheimer complex, for the detection of uncharged 2,4,6-trinitrotoluene (TNT) explosives by developing a terahertz chemical microscope (TCM) imaging system. The organic amine 3-aminopropyltriethoxysilane (APTES) was immobilized on an SiO2-film-coated TCM sensing plate, where it interacted with TNT molecules. The surface electrical potential distribution of TNT, APTES, and the charge-transfer complex was mapped. An electrical potential shift occurred due to the formation of a charge-transfer complex between the electron-rich amino-silane APTES and electron-deficient TNT molecules on the surface of the sensing plate. The electrical imaging and detection of TNT explosives by using the TCM imaging system were demonstrated by measuring the amplitude of the terahertz pulse caused by this electrical potential shift. N-(2-Aminoethyl)-3-aminopropyltrimethoxysilane and N1-(3-trimethoxysilylpropyl)diethylenetriamine were used for further evaluation and comparison of color changes arising from the amine-TNT interactions. The results have shown that TCM imaging is a promising method for the detection of uncharged TNT explosives at a low (sub-parts-per-million) concentration.
Funder
Japan Society for the Promotion of Science
Okayama Foundation for Science and Technology
Publisher
The Electrochemical Society
Subject
Materials Chemistry,Electrochemistry,Surfaces, Coatings and Films,Condensed Matter Physics,Renewable Energy, Sustainability and the Environment,Electronic, Optical and Magnetic Materials
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献