Author:
Lay Nicole,Duquette David
Abstract
Surface roughness of both seed layers and electrodeposited copper for ULSI interconnects affect adhesion and fracture characteristics of the electrodeposited plate. In this program experiments were performed on copper, deposited from complexing citrate baths, directly onto TaN barrier layers, as a function of copper thickness (as measured by plating time) and subsequent annealing. It has been shown that surface roughness increase with increasing plate thickness, reaching a constant roughness at a thickness of about 350 nm. Annealing, in order to enhance plate resistivity, has no appreciable effect on surface roughness.
Publisher
The Electrochemical Society
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献