Author:
ZHOU L.,SHI W. D.,BAI L.,LU W. G.,LI W.
Abstract
In the operation process of centrifugal pumps, especially in multi-stage pumps, axial force is one of the main factors which affect the pump safety and reliability. This paper presents the axial force study in a deep-well centrifugal pump (DCP) with theoretical calculation, numerical simulation and experimental measure. Three different calculation formulas were respectively introduced and used in the model pump. The calculated results were compared and analyzed with the numerical simulation values and experimental results, and the detailed numerical simulation methods and experimental configuration were explained. Finally, the more accurate formula for calculating the axial force in oblique flow centrifugal impeller was selected out. At the rated flow point, the deviation of the axial force obtained by numerical simulation and the experimental value is approximately 3.8%, and the calculated result of selected formula only less than the experimental results of 2.6%. The results provide a theoretical basis for the axial force calculation in the centrifugal impeller design process.
Publisher
EdiUNS - Editorial de la Universidad Nacional del Sur
Subject
Mechanical Engineering,General Chemical Engineering,General Chemistry
Cited by
4 articles.
订阅此论文施引文献