Comparison of ventilation parameters and blood gas analysis in mechanically-ventilated children who received chest physiotherapy and suctioning vs. suctioning alone

Author:

Elizabeth Monalisa,Yoel Chairul,Ali Muhammad,Loebis M. Sjabroeddin,Arifin Hasanul,Sianturi Pertin

Abstract

Background Chest physiotherapy and suctioning are routine methods for airway clearance in mechanically-ventilated children. However, chest physiotherapy has not been confirmed to affect ventilation parameters, such as tidal volume (TV), peak inflation pressure (PIP), peak inspiratory flow (PIF), and peak expiratory flow (PEF), as well as blood gas analysis (BGA) values in pediatric intensive care unit (PICU) patients.Objective To determine the efficacy of chest physiotherapy and suctioning vs. suctioning alone for improving the mechanical ventilation parameters and BGA.Methods This randomized, single-blind, clinical trial was conducted from November 2012 to June 2013 in the PICU at Haji Adam Malik Hospital, Medan. A total of 40 mechanically-ventilated pediatric patients were enrolled and divided into either the chest physiotherapy and suctioning group (24 subjects) or the suctioning alone group (16 subjects). Subjects underwent treatment, followed by monitoring of their ventilation parameters and blood gas analyses. Data were analyzed by independent t-test and Mann-Whitney test.Results Subjects comprised of 23 boys and 17 girls, with an age range of 1–204 months. After the respective treatments (chest physiotherapy and suctioning vs. suctioning alone), the ventilation parameters were as follows: median TV (60.0 vs. 56.5 mL, respectively; P=0.838), median PEF (10.4 vs. 10.8 I/s, respectively; P=0.838), median PIF (7.4 vs. 8.2 I/s, respectively; P=0.469), and mean PIP (17.3 vs. 15.6 cmH2O, respectively; P=0.23). The BGA values were: median pH (7.4 vs. 7.3, respectively; P=0.838), median pCO2 (38.4 vs. 36.2 mmHg, respectively; P=1.000), mean pO2 (136.6 vs. 139.2 mmHg, respectively; P=0.834), median HCO3 (20.4 vs. 22.7 mmol/L, respectively; P=0.594), median TCO2 (22.0 vs. 23.7 mmol/L, respectively; P=0.672), mean BE (-4.3 vs. -3.1 mmol/L, respectively; P=0.629), and median O2 saturation  (98.5 vs. 98.3 %, respectively; P=0.967).Conclusion In mechanically-ventilated children in the PICU, ventilation parameters and BGA values are not significantly different between subjects who received both chest physiotherapy and suctioning and those who received suctioning alone.

Publisher

Paediatrica Indonesiana - Indonesian Pediatric Society

Subject

Pediatrics, Perinatology and Child Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3