Affiliation:
1. Izhevsk State Agricultural Academy
Abstract
THE PURPOSE. The asynchronous electric motor with a squirrel cage rotor is widely used in the electric driven industry and agricultural machinery. One of the possible ways to improve its energy characteristics is to use a combined 12-zone stator winding instead of the standard 6-zone one. However, in a combined winding with a parallel connection of the «star» and «delta» phases, the phases may not be loaded equally. Therefore, the main purpose of the work under analysis is to study the distribution of currents between the phases of the «star» and «delta» in the asynchronous motor with a combined winding.METHODS. The study was performed on the AIR71V4 engine, rewound onto a combined winding, in which the real ratio of the active resistances of the «delta» and «star» turned out to be 7% less than the theoretical one. The tests were carried out in no-load and short-circuit mode when powered from a three-phase network, as well as in short-circuit mode when one of the line wires is broken.RESULTS. The work gives the values of the currents flowing through the phases of the combined winding. For the experimental sample, the deviation of the obtained currents from the theoretical values is determined. Equations of currents are obtained when one of the linear wires is broken. Schemes for switching on the main contacts of a thermal relay for a motor with a combined winding are proposed.CONCLUSION. The results of the study showed that in an asynchronous motor with a combined winding, in which the real ratio of the active resistances of the «delta» and «star» is less than the theoretical one, the current is not proportionally distributed over the phases. The most preferred circuit for switching on a thermal relay is one in which its main contacts are connected to the «delta» phases, and the thermal relay must be three-pole.
Publisher
Kazan State Power Engineering University
Subject
Pharmacology (medical),Complementary and alternative medicine,Pharmaceutical Science
Reference18 articles.
1. Meshcheryakov VN, Sibirtsev DS, Valtchev S, Gracheva EI. Control system for a frequency synchronized asynchronous electric drive Power engineering: research, equipment, technology. 2021;23(3):116-126. doi:10.30724/1998-9903-2021-23-3-116-126.
2. Ivanovа VR, Kiselev IN. Frequency-adjustable electric drive for energy saving and optimization of technological processes in electrical complexes. Power engineering: research, equipment, technology. 2019; 21(5):59-70. doi:10.30724/1998-9903-2019-21-5-59-70.
3. Romanova VV, Khromov SV, Suslov KV. Analysis of influencing factors affecting the operational reliability of low-voltage asynchronous electric motors. Power engineering: research, equipment, technology. 2021;23(3):80-89. doi:10.30724/1998-9903-2021-23-3-80-89.
4. Khorolskiy VYa. Ekspluatatsiya elektrooborudovaniya selskokhozyaystvennykh predpriyatiy. Stavropol; 1996.
5. Ermolaev SA, Masyutkin EP, Yakovlev VF, Ermolaev SA, editors. Ekspluatatsiya energooborudovaniya v selskomk hozyaystve. Kiyev: Inkos; 2005.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献