Affiliation:
1. Ulyanovsk State Technical University
Abstract
THE PURPOSE. Assessment of the state of the art in the development of current limiters based on liquid metal self-healing fuses and an increase in the switching life of self-healing fuses with a composite fuse-link.METHODS. When solving the problem, the method of literature analysis was used, as well as the method for calculating dependencies for different materials of the fuse-link, the implemented method of scientific computer mathematics.RESULTS. Literary sources contain information about the designs of liquid-metal self-healing fuses and their research, allowing conclusions to be drawn about their viability and the possibility of obtaining a practical yield. A common disadvantage of the of liquid-metal self-healing fuses design is a limited switching resource due to an increase in the diameter of the fuse-link under the action of arc erosion. A significant effect of increasing the switching resource and the stability of the protective characteristic is possessed by the design of a of liquid-metal self-healing fuses with a composite fusible link. However, in such designs, the switching capacity is reduced. It is shown that the main criterion for the operability of the liquid-metal self-healing fuses with a composite fusible link is the value of the ratio between the value of the shunting resistance and the resistance of the electric ARC. The performance of the liquid-metal self-healing fuses with a composite fusible link is ensured at values of this value below critical.CONCLUSION. The proposed mathematical expression may turn out to be useful in the development of liquid-metal self-healing fuses with a composite fusible link design, for example, when choosing an electrode material, liquid metal, etc. This will significantly increase the switching resource of the liquid-metal self-healing fuses with a composite fusible link. The condition must be taken into account in the parametric synthesis of the current limiter based on the liquid-metal self-healing fuses with a composite fusible link.
Publisher
Kazan State Power Engineering University
Subject
Pharmacology (medical),Complementary and alternative medicine,Pharmaceutical Science
Reference15 articles.
1. Kuznetsov AV. Liquid Metal Fuse and Investment Attractiveness of Their Development. Energoatomizdat. Moscow. 2006. p. 297.
2. Voronin AA, Kireev KV, Kulakov PA, et al. Experience in the Application of Liquid-Metal Working Medium in High-Current Commutators and Contact Joints. Russian Electrical Engineering. 2008;79(8):415-419. Available at URL: https://elibrary.ru/item.asp?id=13576205
3. Kuzhekov SL, Vasiliev BN, Kurov NN. Design features of liquid metal self-healing fuses and their influence on the processes occurring in them. News of universities. Electromechanics. Special Issue. 2010:53 -55. Available at URL: https://elibrary.ru/item.asp?id=17783697
4. Smolencev NI, Chetoshnikova LM. Electric network topology and method of transmission of electric energy. Power engineering: research, equipment, technology. 2019;21(4):95-103. Available at URL: https://www.elibrary.ru/item.asp?id=41450788.
5. Chetoshnikova LM, Smolencev NI, Chetoshnikov SA, et al. Autonomous power supply systems with renewable sources of energy and smart grid. Power engineering: research, equipment, technology. 2018;20(5-6):3-10. Available at URL: https://www.elibrary.ru/item.asp?id=35418838