Affiliation:
1. Ufa State Petroleum Technical University
Abstract
OBJECT. When developing DC test voltage sources to assess the insulation quality of high-voltage equipment, the task is to measure the leakage current flowing through the test object. METHODS. When solving the problem the authors proposed a technical solution for measuring the current flowing through the test when testing insulation with rectified voltage, which uses a precision resistor, an isolating amplifier, a 2-channel operational amplifier with a unipolar power supply, zero voltage drift, and an ADC of a microcontroller.RESULTS. The article in the course of the study of the stand of the circuit for measuring the leakage current flowing through the tested object when testing the insulation with rectified voltage, an experimental industrial sample was created, which makes it possible to measure the leakage current value in the range from 10 μA to 1000 μA. The use of the developed circuit for measuring the current flowing through the test object when testing the insulation with rectified voltage makes it possible to calculate the DC component of the voltage signal from the alternating signal and in real time, and, therefore, to quickly monitor the current in high-voltage circuits for continuous monitoring. CONCLUSION. So the introduction of this sample will make it possible, on its basis, to create a number of digital measuring microammeters that make it possible to measure the leak-age current in high-voltage test installations for testing the insulation of objects from 15 nF to 200 nF, in the leakage current measurement range from 10 μA to 1000 μA. The results obtained can be used in high voltage technology to study circuits for measuring the leakage current flowing through the test object when testing insulation with rectified voltage.
Publisher
Kazan State Power Engineering University
Subject
Pharmacology (medical),Complementary and alternative medicine,Pharmaceutical Science
Reference24 articles.
1. Kozlov VK, Kirzhatskikh ER. Autonomous capacitive power supply for devices for measuring parameters of overhead power transmission lines. Proceedings of Higher Educational Institutions. Energy problems. 2017;19;3-4;63.
2. Mugalimov RG, Mugalimova AR., Kalugin YuA et al. Methodology for diagnostics and identification of malfunctions of windings of an induction motor in the mode of its operation. Electrotechnical systems and complexes. 2018;3(40);70-78.
3. Malev NA, Mukhametshin AI, Pogoditsky OV, et al. Experimental and analytical identification of the mathematical model of an electromechanical DC converter using the least squares method. Proceedings of Higher Educational Institutions. Energy problems. 2019;21;4.113- 122.
4. Voltage characteristics of electricity supplied by public electricity networks; German version EN 50160:2010/A1:2015, 7 c. Available at: URL https://www.en-standard.eu/din-en-50160-a3-merkmale-derspannung-in-offentlichenelektrizitatsversorgungsnetzen-deutsche-und-englische-fassung-en-50160-2010-pra3-2017/. Accessed to 20.12.2018
5. Suslov KV, Solonina NN, Gerasimov DO. Modern approaches to assessing the quality of electrical energy. Proceedings of Higher Educational Institutions. Energy problems. 2017;19;7- 8;85-93.