Abstract
The herbicide glyphosate is the most widely used pesticide worldwide. Glyphosate and its major metabolite, aminomethylphosphonic acid (AMPA), have been frequently found in water samples. The widely used methods for determining these compounds are expensive and environmentally unfriendly due to reagent consumption for derivatization. Another possibility is the use of classic ion chromatography, albeit with low sensitivity and subject to interferences. Therefore, this study aimed to develop a method to directly and simultaneously determine glyphosate, AMPA, and common inorganic anions in water samples using gradient capillary ion chromatography without sample pre-treatment and derivatization. The proposed method was validated, presenting adequate linearity for glyphosate and AMPA with a determination coefficient (r2 ) > 0.998. Recoveries ranged from 94 to 105% and 79 to 113% for glyphosate and AMPA, respectively, with a relative standard deviation < 10%. The practical method limits of detection and quantification for both glyphosate and AMPA were 7.5 and 25 µg L-1, respectively. The method presented satisfactory results for the anions fluoride, chloride, bromide, nitrite, nitrate, phosphate, and sulfate, with limits of detection ranging from 7.5 to 200 µg L-1. Application of the method in water samples proved simple, efficient, and cost-effective, enabling the monitoring of these analytes in different water matrices.