A Comparison of the Accuracy of Digital and Conventional Radiography in the Diagnosis of Recurrent Caries

Author:

Anbiaee Najmeh,Mohassel Anousheh Rashed,Imanimoghaddam Mahrokh,Moazzami Seyed Mostafa

Abstract

Abstract Aim The purpose of this laboratory research was to compare the accuracy of digital and conventional bitewing radiographs in the diagnosis of recurrent caries under class II amalgam restorations. Methods and Materials This study involved 82 posterior intact teeth in which class II amalgam boxes were prepared. Carious lesions were simulated in half of the proximal boxes in the intersection between the facial or lingual wall and the gingival floor or midway between the facial and lingual walls. The other half of each tooth specimen served as a control. The prepared boxes were then restored with a Tytin FC (Kerr, USA) amalgam. The teeth were radiographed in the bucco-lingual direction to obtain images comparable to bitewing. Digital radiographs made with an intraoral CCD sensor and conventional radiography with dental E film were used. Three expert observers evaluated both types of images for the diagnosis of recurrent caries. Results Sensitivity and specificity values for direct digital radiography were 73 and 95 percent at the buccal and lingual line angles, respectively, and 29 and 90 percent at the mid-gingival floor, respectively. These corresponding values for conventional radiography were respectively 63 and 93 percent at the buccal line angle, 61 and 93 percent at the lingual line angle, and 44 and 95 percent at the mid-gingival floor. The total sensitivity and specificity values were 58 and 93 percent for digital radiography and 56 and 93 percent for conventional radiography. The overall accuracy was 76 percent for digital and 75 percent for conventional radiography. No significant difference in specificity or sensitivity was found between the digital and conventional radiography (p=0.104). Separately, no significant difference was seen between the buccal line angle and the mid-gingival floor, but a significant difference was seen between the two methods in the lingual line angle (p=0.004). Conclusion The digital and conventional bitewing radiographs had similar diagnostic accuracy for the diagnosis of recurrent caries. Lesions located at the buccal or lingual line angle were more easily detected than those at the mid-gingival region. Clinical Significance Although there was no significant difference between digital and conventional radiography in the diagnosis of recurrent caries, digital radiography requires less ionizing radiation, making this method of imaging suggested for routine dental practice. Citation Anbiaee N, Rashed A, Imanimoghaddam M, Moazzami SM. A Comparison of the Accuracy of Digital and Conventional Radiography in the Diagnosis of Recurrent Caries. J Contemp Dent Pract [Internet]. 2010 December; 11(6):025-032. Available from: http://www.thejcdp.com/journal/ view/volume11-issue6-anbiaee

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3