A Study to Evaluate and Compare the Shear Bond Strength of Resilient Liners with Heat Cure Denture Base Resins, with and without the Effect of Saliva: An in vitro Study

Author:

Reddy K Srinivas,Rao N Venugopal,Rao C Satyanageshwar,Reddy S Sreedhar,Prasad G Maruthi,Naik Madhukeshwara S

Abstract

ABSTRACT Aim To evaluate and compare the shear bond strength of resilient liners with heat cure denture base resins in the presence or absence of saliva. Materials and methods Two commercially available heat polymerized acrylics and three commercially available denture liners were immersed in artificial saliva for 7 days and 14 days, respectively. A total of 180 (Acralyn-H, No.90 and Lucitone - 199, No.90) specimens were prepared. Total of 90 overlapping joint specimens were prepared, 45 of them using Acralyn H (AGroup) and rest 45 using Lucitone-199 (L-Group). The specimens were tested for flexural strength with a 3-point bending test on an Instron universal testing machine. The results were analyzed with a one-way analysis of variance (ANOVA). Results The mean difference in shear bond strength (SBS) at different time intervals was found to be statistically significant (p < 0.001). Lucitone-199 recorded a significantly higher mean SBS compared to Acralyn H (p < 0.001). Further, significant differences between GC and Densply, GC and Aswin liners, and between Dentsply and Aswin were noted (p < 0.001). Difference between baseline and 7 days time interval, as well as, between baseline and 14 days time interval with respect to the mean SBS of these materials were significant (p < 0.001). Also, the mean difference in SBS between 7 days time interval and 14 days time interval was statistically significant (p < 0.001). Among the three different liners, GC yielded a higher mean SBS compared to Aswin and Dentsply at all the three time intervals. The mean SBS recorded in Dentsply and Aswin was almost same at 14 days time interval, but at baseline and 7 days, it was higher in Aswin compared to Dentsply. Conclusion Lucitone-199 recorded a higher mean SBS compared to Acralyn H. As the time interval increases, the mean SBS recorded in both the denture base materials decrease. Among the three different liners, GC yields a higher mean SBS compared to Aswin and Dentsply at all the three time intervals. Clinical significance The most common reason for failures of resilient linings in removable dentures is the separation of these linings from the denture base. Therefore, poor adhesive bond properties are one of the serious defects of the material in clinical practice. How to cite this article Rao CS, Reddy SS, Prasad GM, Reddy KS, Rao NV, Naik MS. A Study to Evaluate and Compare the Shear Bond Strength of Resilient Liners with Heat Cure Denture Base Resins, with and without the Effect of Saliva: An in vitro Study. J Contemp Dent Pract 2012;13(3):394-400.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3