Flute and Shank Dimensions of Reciprocating Instruments before and after Simulated Root Canal shaping

Author:

Estrela Carlos,Sampaio Felipe C,Brito Ana PP,Veloso Heloisa HP,de Alencar Ana HG,de A Decurcio Daniel,de Figueiredo José AP

Abstract

ABSTRACT Aim This study analyzed the effect of the dimensions of the flute and shank in the first 4 mm of instrument tips on the deformation and dimensional changes of reciprocating instruments after root canal shaping (RCS). Materials and methods The reciprocating instruments used were Reciproc® R25, R40, and R50; WaveOne® Small, Primary, and Large; and Unicone® #20, #25, and #40. Scanning electron microscopy images of the first 4 mm of the tip were acquired at 30× magnification before and after simulated curved root canals were shaped. Each instrument was used only once. The images were transferred to the AxioVision® software to measure the flute area (µm2, shank area (µm2), flute length (µm), and crosssectional diameter (µm). Student's t test for paired samples was used to compare differences before and after RCS, and analysis of variance followed by the Tukey test, to compare differences between instruments of similar sizes. The instruments were classified according to deformations after RCS. Results Reciproc® instruments had larger flutes and smaller shanks. The Reciproc® R40 had significant differences in crosssectional diameter at 0.5 mm from the tip. Reciproc® had no plastic deformations. Unicone® #20 instruments had significant differences in cross-sectional diameter at 1.5 and 3.0 mm from the tip, and #25 instruments had differences at 1.5 and 3.0 mm and in length of the second and third flutes. One #20 and three #40 instruments had plastic deformations. The differences in length of the first and fourth flutes of WaveOne® Primary and in cross-sectional diameter at 2.0 mm from the tip of WaveOne® Large were significant. Two of three WaveOne® Large instruments had plastic deformations. Conclusion Reciproc® instruments had greater flute areas and lengths and smaller shanks than Unicone® and WaveOne® instruments of similar sizes. Reciproc® instruments had a greater flute-to-shank ratio. WaveOne® instruments had the lowest flute-to-shank ratio. Unicone® instruments had the most plastic deformations. Instruments with larger flutes and smaller shanks had fewer plastic deformations after curved RCS. Clinical significance The knowledge of mechanical behavior before choosing the endodontic instrument may avoid fracture, regardless of the clinical condition, and it is essential to the success of root canal treatment. How to cite this article Sampaio FC, Brito APP, Veloso HHP, Alencar AHG, Decurcio DA, Figueiredo JAP, Estrela C. Flute and Shank Dimensions of Reciprocating Instruments before and after Simulated Root Canal shaping. J Contemp Dent Pract 2017;18(3):198-204.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3