Frictional Resistance between Orthodontic Brackets and Archwire: An in vitro Study

Author:

Kumar Avinash,Husain Nadeem

Abstract

ABSTRACT Aim The purpose of this investigation was to determine the kinetic frictional resistance offered by stainless steel and Titanium bracket used in combination with rectangular stainless steel wire during in vitro translatory displacement of brackets. Materials and methods In this study. Brackets: (All brackets used had a torque of – 7° and an angulation of 0°): (1) Dynalock (Unitek) 0.018” slot, 3.3 mm bracket width, (2) Mini Uni-Twin (Unitek) 0.018” slot, 1.6 mm bracket width, (3) Ultra-Minitrim (Dentaurum) 0.022” slot 3.3 mm bracket width, (4) Titanium (Dentaurum) 0.022” slot, 3.3 mm bracket width. WIRES: (1) 0.016 × 0.022” stainless steel (Dentaurum), (2) 0.017 × 0.025’'stainless steel (Unitek), (3) 0.018 × 0.025” stainless steel (Dentaurum), elastomeric modules (Ortho Organisers), 0. 009” stainless steel ligature wires, hooks made of 0.021 × 0.025” stainless steel wires, super glue to bond the hooks to the base of the bracket, acetone to condition the bracket and wires before testing and artificial saliva. Brackets were moved along the wire by means of an Instron universal testing machine (1101) and forces were measured by a load cell. All values were recorded in Newtons and then converted into gms (1N-102 gm). 200 gm was then subtracted from these values to find out the frictional force for each archwire/bracket combination. For each archwire/ bracket combination three readings were taken under wet and dry condition and also with stainless steel ligature and elastomeric modules separately. Results The results showed that narrow brackets generated more friction than wider brackets. Frictional force was directly proportional to wire dimension. Titanium brackets generated more friction than stainless steel brackets. Archwire and bracket ligated with elastomeric module generated more friction than when ligated with stainless steel ligature wire. Frictional forces in the wet condition were greater than in the dry condition for all archwire to bracket combinations. Conclusion Frictional force was seen to be inversely proportional to bracket width, frictional force was inversely proportional to bracket width, and in the wet condition were greater than in the dry condition for all archwire to bracket combinations. Clinical significance This study of friction is its role in lessening the force actually received by a tooth from an active component such as a spring, loop or elastic. Hence greater applied force is needed to move a tooth with a bracket archwire combination demonstrating high magnitudes of friction compared with one with a low frictional value. How to cite this article Husain N, Kumar A. Frictional Resistance between Orthodontic Brackets and Archwire: An in vitro Study. J Contemp Dent Pract 2011;12(2):91-99.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3