Verification of the Accuracy of Electronic Mandibular Movement-recording Devices: An in vitro Investigation

Author:

Ahuja Swati,Scarbecz Mark,Balch Heath,R Cagna David

Abstract

ABSTRACT Aims and objectives To determine the accuracy of an opto-electronic pantograph (Freecorder Bluefox, Dentron) in locating a known transverse horizontal axis (THA); To determine the accuracy of the opto-electronic pantograph and the mechano-electronic pantograph (Cadiax Compact 2, Whip Mix Corp) in recording preset condylar control values; and additionally, compare the accuracy of the opto-electronic and mechano-electronic pantographs with each other. Materials and methods A fully adjustable articulator (Denar D5A, Whip Mix Corp) was employed as a mock patient. True condylar control settings and condylar control values determined by each recording device were documented and statistically analyzed using 2-sample independent t-tests (p < 0.05). Results Statistical data analysis indicated that (1) the opto-electronic pantograph did not accurately locate the known THA; (2) the condylar control values registered by opto-electronic and the mechano-electronic pantographs were statistically different from the preset condylar control values; and (3) different degrees of accuracy existed between the opto-electronic pantograph and mechano-electronic pantograph. Conclusion Errors up to 5 mm in the location of the THA may not have much clinical significance. The majority of articulator condylar control settings predicted by the opto-electronic and mechano-electronic pantographs investigated in this study were statistically different. Clinically, the predicted mean values for the lateral condylar inclination (LCI) and progressive mandibular lateral translation (PMLT) were within 5° of the known mock patient settings. However, the medial wall angulation and immediate side shift values obtained from the opto-electronic instrument suffered from large errors. Clinical implication Practical goals for complex restorative dentistry often include attaining accurate occlusal relationships, simulating the patient's mandibular movements in the laboratory using three-dimensional instrumentation and achieving desired occlusal contacts and relationships. Clinicians may rely on mandibular motion-recording devices to render accurate and useful information. Cost of purchase of electronic mandibular motion-recording devices (opto-electronic and mechano-electronic recorders), their accuracy, and time required for training should be compared with the use of conventional pantographs. The use of electronic pantograph may lead to savings in time and efforts over conventional pantograph and interocclusal records. How to cite this article Balch H, Cagna DR, Ahuja S, Scarbecz M. Verification of the Accuracy of Electronic Mandibular Movement-recording Devices: An in vitro Investigation. Int J Experiment Dent Sci 2017;6(2):84-94.

Publisher

Jaypee Brothers Medical Publishing

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3