Author:
Rajasekaran UB,Sandbhor Shailesh,Ramees M Mohamed,Abraham Esther A
Abstract
ABSTRACT
Aim
The purpose of this research is to compare the frictional attributes of stainless steel conventional brackets and selfligating stainless steel brackets with different dimensions of archwires.
Materials and methods
The test was carried with two sets of maxillary brackets: (1) Conventional stainless steel (Victory Series), (2) stainless steel self-ligating (SmartClip) without first premolar brackets. Stainless steel, nickel–titanium (NiTi), and beta-Ti which are the types of orthodontic wire alloys were tested in this study. To monitor the frictional force, a universal testing machine (Instron 33R 4467) that comprises 10 kg tension load cell was assigned on a range of 1 kg and determined from 0 to 2 kg, which allows moving of an archwire along the brackets. One-way analysis of variance was used to test the difference between groups. To analyze the statistical difference between the two groups, Student's t-test was used.
Results
For Victory Series in static friction, p-value was 0.946 and for kinetic friction it was 0.944; at the same time for SmartClip, the p value for static and kinetic frictional resistance was 0.497 and 0.518 respectively. Hence, there was no statistically significant difference between the NiTi and stainless steel archwires.
Conclusion
It is concluded that when compared with conventional brackets with stainless steel ligatures, self-ligating brackets can produce significantly less friction during sliding. Beta-Ti archwires expressed high amount of frictional resistance and the stainless steel archwires comprise low frictional resistance among all the archwire materials.
Clinical significance
In orthodontics, frictional resistance has always had a major role. Its ability to impair tooth movement leads to the need for higher forces to move the teeth and it extends the treatment time which results in loss of posterior anchorage. Friction in orthodontics is related with sliding mechanics when a wire is moving through one or a series of bracket slots.
How to cite this article
Sridharan K, Sandbhor S, Rajasekaran UB, Sam G, Ramees MM, Abraham EA. An in vitro Evaluation of Friction Characteristics of Conventional Stainless Steel and Selfligating Stainless Steel Brackets with different Dimensions of Archwires in Various Bracket–archwire Combination. J Contemp Dent Pract 2017;18(8):660-664.
Publisher
Jaypee Brothers Medical Publishing
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献