Author:
Facchini Fátima MM,Filho Mario Vedovello,Vedovello Silvia AS,Cotrim Flávio A,Cotrim-Ferreira Andréa,Tubel Carlos AM
Abstract
ABSTRACT
Objective
To evaluate the difference in surface roughness of stainless steel archwires of different commercial brands used in lingual orthodontics.
Materials and methods
Precontoured arches measuring 0.016″ × 0.022″ were selected of the following brands: Tecnident, Adenta, G&H, Highland Metals Inc., Ormco, Incognito, and Ebraces. Quantitative evaluation of the surface roughness of archwires was performed by means of an atomic force microscope in contact mode. Three surface readouts were taken of each sample, analyzing areas of 20 × 20 μm. Each scan of the samples produced a readout of 512 lines, generating threedimensional images of the wires. The analysis of variance statistical test was applied to prove significant variables (p > 0.05), with H0 being rejected and H1 accepted.
Results
The Incognito brand showed the lowest surface roughness. The archwires of brands Adenta, Tecnident, Highland, and Ormco showed similar values among them, and all close to these obtained by the Incognito brand. The archwires of the Ebraces brand showed the highest surface roughness, with values being close to those of the G&H Brand.
Conclusion
There was a statistical difference in surface roughness of orthodontic archwires among the brands studied.
Clinical significance
Companies should pay attention to the quality control of their materials, as these may directly affect the quality of orthodontic treatment.
How to cite this article
Facchini FMM, Filho MV, Vedovello SAS, Cotrim FA, Cotrim-Ferreira A, Tubel CAM. Wire Roughness Assessment of 0.016″ × 0.022″ the Technique Lingual Orthodontics. J Contemp Dent Pract 2017;18(4):295-299.
Publisher
Jaypee Brothers Medical Publishing