Evaluation of the Bond Strength and Fracture Resistance of Different Post Systems

Author:

Türker Sevinç Aktemur,Özçelik Bahar,Yilmaz Zeliha

Abstract

ABSTRACT Aim To compare the bond strength and the fracture resistance of different post systems. Materials and methods Endodontically treated 60 mandibular incisor and 60 mandibular premolar teeth were used for the bond strength and fracture resistance test respectively. For each test, three groups (n = 20) were formed according to the posts used zirconia posts (ZR post), individually formed glass fiber reinforced composite posts with an (Interpenetrating Polymer Network—IPN post) and cast metal posts. Then groups were randomly assigned into two subgroups according to the post design: 1-parallel sided and 2-tapered (n = 10/group). All posts were luted with a self-adhesive luting agent. For push-out test two 1 mm thick horizontal root sections were obtained and subjected to push-out test. For fracture resistance test, the specimens were loaded vertically at 1 mm/min crosshead speed. The push out test data were analyzed with Kruskal-Wallis and Dunn's test. Analysis of variance (ANOVA) and Tukey significant difference tests were used to compare the fracture resistance. Results Cast metal posts showed the highest retention (p < 0.05); however, IPN and zirconia posts showed similar results. No significant difference was found between parallel sided or tapered designs of post groups in terms of bond strength (p > 0.05). In terms of fracture resistance, IPN post groups showed lowest fracture resistance (p < 0.05). No significant difference was found between parallel sided or tapered posts in terms of fracture resistance, except zirconia post (p > 0.05). There was no relationship between the bond strength and fracture resistance of the post systems (r = – 0.015, p > 0.700). Conclusion Post type had effect both on the fracture resistance and retention of the posts used. However, post design had effect only on the fracture resistance of the post systems. Clinical significance Superficial treatment of the post used can improve the retention of post systems. How to cite this article Türker SA, Özçelik B, Yilmaz Z. Evaluation of the Bond Strength and Fracture Resistance of Different Post Systems. J Contemp Dent Pract 2015;16(10): 788-793.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3