MyoRing for Central and Noncentral Keratoconus

Author:

Daxer Albert

Abstract

ABSTRACT Purpose To demonstrate treatment options for keratoconus using MyoRing intracorneal implant in central and noncentral cones. Materials and methods Five eyes with central and noncentral cones were compared in a retrospective study. Results In central cones the maximum of the flattening effect is in the corneal center while in noncentral cones the maximum of the flattening is in area of the cone. Conclusion No matter where the cone location is the implantation of MyoRing intracorneal implants always results in a regularization of the central cornea. How to cite this article Daxer A. MyoRing for Central and Noncentral Keratoconus. Int J Kerat Ect Cor Dis 2012;1(2):117-119.

Publisher

Jaypee Brothers Medical Publishing

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3