Micromovement Evaluation of Original and Compatible Abutments at the Implant–abutment Interface

Author:

Berberi Antoine,Maroun Dagher,Kanj Wasfi,Amine El Zoughbi,Philippe Aramouni

Abstract

ABSTRACT Introduction Use of compatible abutments may increase micromovements between the abutments, and the inner part of the implant may increase the stress on marginal bone level. Also micromovement will change the volume of the inner space of the implant–abutment complex. The resulting pumping effect can transport even initially immobile microorganisms from the exterior to the interior and vice versa. Objectives The purpose of the study was to evaluate the mechanical comportment of OsseoSpeed™ Tx implants connected with original and compatible abutments in vitro under simulated clinical loading conditions. Materials and methods A total of 15 OsseoSpeed™ TX implants (4×11 mm) were used and divided into three groups (n = 5). Three types of abutments were used in the study; group I: Five original Ti Design™ abutments, group II: Five Natea™ abutments, and group III: Implanet™ abutments. Abutments used in groups II and III were all compatible with Astra Tech Implant System™. Implants were embedded into resin. Simulating the human masticatory cycle, the axial force vector was increased up to a defined maximum (25, 50, 75, 100, 125, 150, 175, and 200 N) and inclined 30° to the implant axis. A radiograph amplifier was used to convert the X-ray projection into a picture. The visual evaluation of the frames and the provided X-ray videos were evaluated for an existing microgap in width and length between the implant and the abutment. Results An initial width gap was observed in groups II and III in four of the five samples with an average of 6.5 and 5 μm respectively. When the axial forces reach 75 N, only groups II and III demonstrated a gap width of 5.2 ± 3.63 and 4.8 ± 3.03 μm, and a gap length of 5.2 ± 3.63 and 94 ± 125.3 μm respectively. At 200 N, group I showed a gap width of 8.4 ± 1.67 μm and a gap length of 187.6 ± 43.6 μm, while groups II and III showed a gap width of 12.4 ± 3.29 and 22.8 ± 5.76 μm, and a gap length of 387.2 ± 84.36 and 641.2 ± 122.6 μm respectively. Conclusion Within the limitations of this study and under the parameters used and from the resulting data collected, we can presume that the use of compatible components leads to significant micromovement when compared with the use of original ones. Clinical significance The use of compatible prosthetic components with original implants showed significant micromovements when compared with the use of abutment and implant from the same manufacturer. Clinically, the micromovements when associated with leakage leads to bone loss around the neck of the implant and later to peri-implantitis. How to cite this article Berberi A, Maroun D, Kanj W, Amine EZ, Philippe A. Micromovement Evaluation of Original and Compatible Abutments at the Implant–abutment Interface. J Contemp Dent Pract 2016;17(11):907-913.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3