Wear Resistance of Bulk-fill Composite Resin Restorative Materials Polymerized under different Curing Intensities

Author:

Alkhudhairy Fahad

Abstract

ABSTRACT Introduction The aim of this study was to assess the wear resistance of four bulk-fill composite resin restorative materials cured using high- and low-intensity lights. Materials and methods Twenty-four samples were prepared from each composite resin material (Tetric N-Ceram, SonicFill, Smart Dentin Replacement, Filtek Bulk-Fill) resulting in a total of 96 samples; they were placed into a mold in a single increment. All of the 96 samples were cured using the Bluephase N light curing unit for 20 seconds. Half of the total specimens (n = 48) were light cured using high-intensity output (1,200 mW/cm2), while the remaining half (n = 48) were light cured using low-intensity output (650 mW/cm2). Wear was analyzed by a three-dimensional (3D) noncontact optical profilometer (Contour GT-I, Bruker, Germany). Mean and standard deviation (SD) of surface loss (depth) after 120,000 cycles for each test material was calculated and analyzed using one-way analysis of variance (ANOVA) with a significance level at p < 0.05. Results The least mean surface loss was observed for SonicFill (186.52 µm) cured using low-intensity light. No significant difference in the mean surface loss was observed when comparing the four tested materials with each other without taking the curing light intensity into consideration (p = 0.352). A significant difference in the mean surface loss was observed between SonicFill cured using high-intensity light compared with that cured using low-intensity light (p < 0.001). Conclusion A higher curing light intensity (1,200 mW/cm2) had no positive influence on the wear resistance of the four bulk-fill composite resin restorative materials tested compared with lower curing light intensity (650 mW/cm2). Furthermore, SonicFill cured using low-intensity light was the most wearresistant material tested, whereas Tetric N-Ceram cured using high-intensity light was the least wear resistant. Clinical significance The wear resistance was better with the newly introduced bulk-fill composite resins under low-intensity light curing. How to cite this article Alkhudhairy F. Wear Resistance of Bulk-fill Composite Resin Restorative Materials Polymerized under different Curing Intensities. J Contemp Dent Pract 2017;18(1):39-43.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3