Author:
Can Gülsen,Özmumcu Baransel,Altinci Pinar
Abstract
ABSTRACT
Aim
To investigate the importance of attachment types on the retention loss of extracoronal attachment-retained removable partial dentures depending on the usage period.
Materials and methods
In order to observe the retention loss of 5 different attachments (OT Strategy, OT Strategy-metal protected, Vario-stud-snap and Vario-soft 3 and ERA-RV) over time, attachment-retained partial dentures representing Kennedy II mod. I case were placed in a custom-made, retention test machine. For each minute, eight separating and joining movements were performed and retention values (Newton) of the attachments were recorded by computer. The retention tests implemented in 540,1080 and 2160 cycles. The data were evaluated statistically according to the two-way ANOVA and Tukey parametrical tests.
Results
The slide type attachment providing the best retention force was observed to be the most worn out by this process (p < 0.01) while the ball type attachments, which typically have the lesser retention force, showed less retention loss (p < 0.01).
Conclusion
It can be concluded that the retention attributes of the attachment-retained dentures were affected by the specific type of precision attachment as well as the usage period.
Clinical significance
Precision attachments with ball-type plastic matrices may be recommended for the clinical use due to their retention stability over time.
How to cite this article
Can G, Özmumcu B, Altinci P. In vitro Retention Loss of Attachment-retained Removable Partial Denture. J Contemp Dent Pract 2013;14(6):1049-1053.
Publisher
Jaypee Brothers Medical Publishing
Reference52 articles.
1. Phoenix RD, Cagna DR, DeFreest CF. Direct Retainers, indirect retainers and tooth replacements. In: Stewart's clinical removable partial prosthodontics. 3rd ed. Chicago: Quintessence; 2003. p.19.
2. Carr AB, Mc Givney GP, Brown DT. Direct Retainers. In: Mc Cracken's removable partial prosthodontics. 11th ed. Missouri: Mosby. 2005.p. 79-81.
3. A classification of precision attachments
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献