In vitro Retention Loss of Attachment-retained Removable Partial Denture

Author:

Can Gülsen,Özmumcu Baransel,Altinci Pinar

Abstract

ABSTRACT Aim To investigate the importance of attachment types on the retention loss of extracoronal attachment-retained removable partial dentures depending on the usage period. Materials and methods In order to observe the retention loss of 5 different attachments (OT Strategy, OT Strategy-metal protected, Vario-stud-snap and Vario-soft 3 and ERA-RV) over time, attachment-retained partial dentures representing Kennedy II mod. I case were placed in a custom-made, retention test machine. For each minute, eight separating and joining movements were performed and retention values (Newton) of the attachments were recorded by computer. The retention tests implemented in 540,1080 and 2160 cycles. The data were evaluated statistically according to the two-way ANOVA and Tukey parametrical tests. Results The slide type attachment providing the best retention force was observed to be the most worn out by this process (p < 0.01) while the ball type attachments, which typically have the lesser retention force, showed less retention loss (p < 0.01). Conclusion It can be concluded that the retention attributes of the attachment-retained dentures were affected by the specific type of precision attachment as well as the usage period. Clinical significance Precision attachments with ball-type plastic matrices may be recommended for the clinical use due to their retention stability over time. How to cite this article Can G, Özmumcu B, Altinci P. In vitro Retention Loss of Attachment-retained Removable Partial Denture. J Contemp Dent Pract 2013;14(6):1049-1053.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

Reference52 articles.

1. Phoenix RD, Cagna DR, DeFreest CF. Direct Retainers, indirect retainers and tooth replacements. In: Stewart's clinical removable partial prosthodontics. 3rd ed. Chicago: Quintessence; 2003. p.19.

2. Carr AB, Mc Givney GP, Brown DT. Direct Retainers. In: Mc Cracken's removable partial prosthodontics. 11th ed. Missouri: Mosby. 2005.p. 79-81.

3. A classification of precision attachments

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3