Comparison between Acetal Resin and Cobalt-chromium Removable Partial Denture Clasps: Effect on Abutment Teeth Supporting Structures

Author:

Mohamed Tarek,Baraka Osama Abdulmoneam,Badawy Magdy Mostafa

Abstract

ABSTRACT Statement of problem Acetal resin has been introduced as an esthetic partial denture clasp material. However, the effects of these clasps on the abutment teeth supporting structures were not clear. Purpose To evaluate the effects of acetal resin clasps on the abutment teeth supporting structures as compared to cobalt-chromium clasps. Materials and methods Twenty patients, 12 males and 8 females, with Kennedy class III modification I partially edentulous maxilla and dentulous mandibles were selected for this study. Patients were divided into two equal groups; group 1 received maxillary cobalt-chromium partial denture frameworks with acetal resin Akers clasps. Group 2 received maxillary partial denture with cobalt-chromium frameworks and Akers cobalt-chromium clasps. Crevicular fluid, epithelial attachment loss, and bone height and density of the abutment teeth were evaluated at partial denture insertion and after 6 and 12 months. Paired t-test was used at p ≤ 0.05 to assess the changes in the above parameters in each group. Student t-test was used to compare between the two groups. Results Crevicular fluid measurements were significantly higher in the first group than that in the second group. There were no differences in epithelial attachment loss between the two groups. There were significantly higher reductions in the bone height and in the bone density in the second group than that in the first group. Conclusion Acetal resin clasps were superior to cobalt-chromium clasps as produced fewer reductions in bone height and in bone density around the abutment teeth inspite of produced increase in the crevicular fluid. Clinical implications Since there were lesser reductions in bone height and in bone density around acetal resin clasp abutments, it could be used successfully to retain partial dentures. However, meticulous oral hygiene and proper insertion and removal of partial denture with acetal resin clasps were required to decrease gingival inflammation and crevicular fluid amount.

Publisher

Jaypee Brothers Medical Publishing

Reference42 articles.

1. Chu CH, Chow TW. Esthetic designs of removable partial dentures. Gen Dent 2003;51:322-24.

2. Sykes LM, Dullabh HD, Chandler HD, Bunn B, Essop AR. Flexibility of technopolymer clasps compared with cobalt- chromium and titanium clasps. SADJ 2002;57:166-71.

3. The physical properties of a polyacetal denture resin

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Esthetic Solutions for Removable Partial Dentures;Removable Partial Dentures;2016