An in vitro Comparative Study to evaluate the Marginal Fit of Castings using Ring and Ringless Casting Techniques with varying Sprue Diameter

Author:

Balakrishnan Dhanasekar,George Vinu T,Dutta Tanuka,Narayan Aparna Ichalangod

Abstract

ABSTRACT Introduction The ultimate success of fixed prosthesis is to pay meticulous attention to the detailed production of the missing tooth structure. Such an accurate replication is technically demanding. Hence, the aim of the study was to evaluate the accuracy of marginal fit of castings with varying sprue diameter and using ring and ringless techniques. Materials and methods Forty standardized wax copings were fabricated on a stainless steel die and divided into two groups. The first group was cast using the metal ring investment technique; the second group was cast using the ringless investment technique. Both the groups were further divided into two groups, each based on the diameter of the sprue (groups I and III: 4.5 mm and groups II and IV: 2.5 mm). The vertical marginal gap was measured at three sites per specimen, using a digital optical microscope at ×100 magnification. The results were analyzed using two-way analysis of variance and independent t-test to determine statistical significance. Results The vertical marginal gaps of castings fabricated using the ringless technique (0.145 ± 0.072 mm) were significantly less (p < 0.001) than those castings fabricated using the conventional metal ring technique (0.264 ± 0.100 mm); however, the vertical marginal gaps of the 2.5 mm sprue diameter (0.199 ± 0.092 mm) and 4.5 mm sprue diameter (0.211 ± 0.118 mm) castings were not statistically significant (p > 0.05). There was also statistically significant interaction (p < 0.001) between group IIA (0.120 ± 0.038 mm) and group IA (0.302 ± 0.098 mm), which was analyzed using the independent t-test. Conclusion It can be concluded that the ringless casting technique in comparison to metal ring technique produces metal castings of better marginal adaptation. Furthermore, the sprue diameter had significant difference wherein the 4.5 mm diameter produced the least vertical discrepancies in the ringless casting technique and 2.5 mm produced lesser vertical discrepancies in the metal ring. Clinical significance One of the key factors that decides the success of a metal-ceramic restoration is the marginal fit. The accurate fit of the restoration greatly minimizes the plaque accumulation, offers good mechanical properties, and reduces micro-leakage and development of secondary caries. The techniques of casting procedure and sprue diameter can have an influence on the outcome. Hence, the current research was undertaken to study the influence of these factors on marginal fit. How to cite this article Dutta T, George VT, Balakrishnan D, Narayan AI. An in vitro Comparative Study to evaluate the Marginal Fit of Castings using Ring and Ringless Casting Techniques with Varying Sprue Diameter. World J Dent 2017;8(2):109-113.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3