Dimensional Accuracy of Multiple Pour Cast from Different Elastomer Impression Techniques

Author:

Haralur Satheesh B,Toman Majed S,Al-Shahrani Abdullah A,Al-Qarni Abdullah A

Abstract

ABSTRACT Context The elastomeric impression material is the most widely used impression material in contemporary dental practice; their accuracy is critical for the outcome of indirect restorations. The accurate duplicate cast obtained from single impression reduces the professional clinical time, patient inconvenience, and extra material cost. Aim To compare the accuracy of the cast obtained from various impression methods utilizing elastomer impression materials. Materials and methods The stainless steel working cast model assembly consisting of two abutments and one pontic area was fabricated. Two sets of six each custom aluminum trays were fabricated, with 5 mm spacer and 2 mm space. The impression methods evaluated in the study were additional silicone putty reline (two step), heavy-light body (one step), monophase (one step), and polyether (one step). Type IV gypsum casts were poured at intervals of 1, 12, 24, and 48 hours. The resultant cast was measured with a traveling microscope for comparative dimensional accuracy. The data obtained were subjected to analysis of variance test at significance level <0.05. Results The die obtained from putty reline two-step impression techniques had the percentage of variation for the height -0.36 to -0.97% with 0.40 to 0.90% increase in diameter. One-step heavy-light body impression dies recorded the increased width by 0.50 to 0.80% and height reduced by - 0.73 to -1.21%. The resultant dies from additional silicone monophase impressions had a percentage of variation for width 1.20% and height by-1.34%. The similar value for width and height for polyether was -1.46% and -1.30% respectively. Conclusion Putty reline technique dies had better dimensional accuracy after repeated pour followed by dies from heavy-light body additional silicone impression. Key message The multiple pour cast from putty reline elastomeric impressions is clinically acceptable, while cast from polyether was smaller in dimension. How to cite this article Haralur SB, Toman MS, Al-Shahrani AA, Al-Qarni AA. Dimensional Accuracy of Multiple Pour Cast from Different Elastomer Impression Techniques. Int J Prosthodont Restor Dent 2016;6(3):51-56.

Publisher

Jaypee Brothers Medical Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3