Comparative Evaluation of Heat-Polymerized and Auto-Polymerized Soft Liners with Regard to Transverse Bond Strength, Peel Bond Strength and Water Sorption: An in vitro Study

Author:

Krishnappan Prasanna Laxmi,Jaiesh Ragavendra,Swaminathan TN

Abstract

ABSTRACT Purpose This is an in vitro study for comparative evaluation of transverse bond strength, peel bond strength and water sorption properties between heat polymerized and auto-polymerized resins. Materials and methods Two denture soft liners (Molloplast-B, Coe-Soft) were investigated. A total number of 60 specimens were used. Twenty specimens were used for evaluation of each physical property of soft liner. For transverse bond strength, ten specimens (64 ⨯ 2.5 ⨯ 10 mm) of each liner were made by processing the denture liners with heat cure polymethyl methacrylate (Meliodent). All specimens for transverse bond strength were conducted on samples immersed in distilled water at 37°C for 50 hours by using three-point transverse flexural tests in a Lloyd's Universal Testing Machine and transverse bond strength was calculated based on the maximum load, span length, breadth and thickness. Another set of ten specimens of (75 ⨯ 25 ⨯ 3 mm) of each denture liner were bonded over 25 mm of heat cure PMMA and separated over the remaining 50 mm of acrylic plate to estimate the peel bond strength. The peel bond strength were conducted on specimens which were dried at room temperature for 48 hours and tested at 21 1 ± C in a Lloyd's testing machine that was linked to an IBM Compatible Computer. The specimens were deformed with a cross head speed of 5 mm/minute according to ASTMD-903 and peel bond strength was calculated when peel angle was 180°. For water sorption tests, ten disc shaped samples of each liner of 50 mm in diameter and 0.5 mm in thickness were fabricated. After polymerization of the liners, the samples were then stored in distilled water at 37°C for 7 days. After one week, excess moisture was removed and each sample was weighed using electronic weighing machine. Results The transverse bond strength of Molloplast-B and Coe-Soft were almost similar and did not show any significant difference in their values. But, there is a significant decrease in the peel bond strength and water sorption property of Molloplast-B and Coe-Soft. Conclusion The reason for transverse bond strength results being similar for both the liners is because they were polymerized chemically with the denture base resins and this chemical affinity could have made its bond strength almost equal. Since, there is a decrease in the peel bond strength of Molloplast-B, the chances of stripping of the liner at the flanges of the denture is minimal. The decrease in water sorption of Molloplast-B can be expected to retain the bond with the denture and sustain the resilience property of the material for a longer time. How to cite this article Krishnappan PL, Jaiesh R, Swa- minathan TN. Comparative Evaluation of Heat-Polymerized and Auto-Polymerized Soft Liners with Regard to Transverse Bond Strength, Peel Bond Strength and Water Sorption: An in vitro Study. Int J Prosthodont Restor Dent 2014;4(3):61-67.

Publisher

Jaypee Brothers Medical Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3