Abstract

Abstract This study was a single-blind, randomized, controlled clinical trial. The researchers evaluated a powered brush/irrigating device (HydraBrush Oral Health System™; OHS) for its safety and ability to deliver a solution to the bottom of 5-6 mm pockets, compared to rinsing alone with a solution following brushing with a powered toothbrush (Sonicare Elite™ 7800; SE). An evaluation technique to measure the quantity and quality of solution able to enter the pocket was also introduced in this project. Methods Subjects were randomized in one of two-groups: brush plus simultaneous irrigation (OHS) versus brush plus rinsing (SE). Subjects used their devices at home for two weeks. At the measurement visit, subjects used the OHS to irrigate and brush simultaneously for 1 minute (30 seconds per each side of the mouth) with a 0.01% erythrosine disclosing solution in 10 oz of distilled water. Control subjects brushed for 2 minutes with a SE followed by a 1 minute rinse with an identical disclosing solution. A blinded evaluator collected six samples of approximately of 1 μL of sucular fluid from six 5-6 mm evaluation sites. This was accomplished by inserting a microcapillary tip with a 20 μL micropipette in the sulcus. Two-group repeated measures ANOVA was used to examine differences in two measures of the disclosing solution between OHS and SE subjects; the spectrometer reading of the disclosing solutions, and by visual inspection of the samples (positive/negative) to determine the presence or absence of solution in the samples. Subjects’ diaries were collected. Bleeding and discomfort during the evaluation period was reported. Results Visually, OHS had a significantly greater proportion of solution taken from the base of 5-6 mm sites than the SE (p=0.0001). However, there was no statistical difference between the two groups (p=.1359) in the spectrophotometer readings. Conclusion The experimental device is more efficient in delivering a solution to the base of 5-6 mm pockets than rinsing following use of a control powered toothbrush. Both devices have demonstrated they are safe and well accepted by patients. The technique developed provides a useful method for quantitative and qualitative studies of solutions from the base of periodontal pockets. Citation Brackett MG, Drisko CL, Thompson AL, Waller JL, Marshall DL, Schuster GS. Penetration of Fluids into Periodontal Pockets Using a Powered Toothbrush/Irrigator Device. J Contemp Dent Pract 2006 July:(7)3:030-039.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

Reference42 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3