Author:
Ozel Emre,Korkmaz Yonca,Attar Nuray
Abstract
Abstract
Aim
The aim of this in vitro study was to investigate the cervical microleakage and internal voids of nanocomposites comparing them with a hybrid composite in Class II restorations with the margins located coronal and apical to the cementoenamel junction (CEJ).
Methods and Materials
Standardized MOD cavities (one cervical margin located in dentin, one in enamel) were prepared in 40 extracted human molars and divided into four groups according to the composite used to restore them (n=10/group). Group 1: Adper Single Bond2/Filtek Supreme XT; Group 2: Excite/Tetric EvoCeram; Group 3: Prime & BondNT/Ceram X; and Group 4 (control) Adper Single Bond2/Filtek Z250. Groups were further divided into subgroups A and B. The “A” subgroups represent the level of the location of the cervial margin at 1 mm coronal to the CEJ, and the “B” subgroups represent the level of the cervical margin located 1 mm apical to the CEJ. After restoration of the cavities with nanocomposites, thermocycling, and immersion in 0.5% basic fuchsin, the dye penetration and internal voids were evaluated under a stereomicroscope. Data were analyzed with the Mann-Whitney U and Kruskal-Wallis tests with the Bonferroni correction for microleakage and with the Chi-square test for internal voids (p<0.05).
Results
The microleakage in the A subgroups was statistically significantly lower then B subgroups (p<0.05). No statistically significant difference was observed in terms of interface, cervical, and occlusal voids for all groups (p>0.05). No significant difference was observed between each group for three voids in all groups (p>0.05).
Conclusion
The location of the gingival margin affects the microleakage of nanocomposites but has no significant affect on the internal voids.
Clinical Significance
Gingival margin located 1 mm coronal to the CEJ provided a reduction in cervical microleakage in nanocomposite restorations.
Citation
Ozel E, Korkmaz Y, Attar N. Influence of Location of the Gingival Margin on the Microleakage and Internal Voids of Nanocomposites. J Contemp Dent Pract 2008 November; (9)7:065-072.
Publisher
Jaypee Brothers Medical Publishing
Reference64 articles.
1. Aguiar FH, Santos AJ, Groppo FC, Lovadino JR. Quantitative evaluation of marginal leakage of two resin composite restorations using two filling techniques. Oper Dent 2002; 27:475-9.
2. Attar N, Turgut MD, Gungor HC. The effect of flowable resin composites as gingival increments on the microleakage of posterior resin composites. Oper Dent 2004; 29:162-7.
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献