Design analysis of a steel industrial building with wide openings exposed to fire

Author:

Cirpici Burak KaanORCID

Abstract

In order to design a fire-resistant steel structure, the change in the physical and mechanical properties of the steel at high temperatures must be known. As the temperature of steel structural elements increases during fire, their strength decreases considerably. After a certain temperature, these strength drops reach critical levels. Therefore, collapses and various deformations (buckling, arching, etc.) occur. To prevent these collapses during the fire, various fire protection materials must be applied to the structural members such as column and beam. Columns are the most critical structural elements in a steel bearing system. While the possible collapse of the columns may cause the collapse of the whole structure, the beams alone may not cause the collapse of the structure, and the column-beam junctions directly affect the spread of fire. Since there will be many openings and gaps in industrial buildings, the spread and growth of a possible fire becomes very serious. Special fire protection measures are therefore required. In this study, the behavior of a steel industrial structure designed and designed under the influence of Standard Fire (ISO 834) was investigated, the distribution of the temperatures in the structural elements was determined, the required fire protection material was selected, and both protected and unprotected steel temperatures were determined. This design against fire is designed to provide fire resistance for 1 hour (60 min) for this structure. During this period, the type and optimum thickness of the protection material to be applied before reaching the critical temperature values for which the strength of the steel material would lose and would be damaged and compared with the temperatures that would occur in the structural elements without applying fire protection. According to the findings of the study, it was concluded that 25 mm drywall box protection material should be applied on the inner columns and 20 mm on the edge columns and 15 mm on the corner columns. In addition to this, it was concluded that spray beams (intumescent coating) of different thicknesses between 15-20 mm were applied to the beams depending on the location and the load to be affected and the type of joint. After these applied passive fire protection materials, the temperatures obtained in the structural elements reached to 500-550 as a result of 1-hour fire design. These temperatures are acceptable temperature values given the strength drop in critical temperature ranges for steel under the 1-hour fire condition.

Publisher

Tulpar Academic Publishing

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3